    Heating capabilities of the Hotline and Autoline at low flow rates.

    • Joerg Schnoor, Ingo Weber, Stephan Macko, Nicole Heussen, and Rolf Rossaint.
    • Department of Anesthesiology, University Hospital Aachen, RWTH Aachen, Germany. joerg.schnoor@gmx.de
    • Paediatr Anaesth. 2006 Apr 1;16(4):410-6.

    BackgroundAt low flow rates, fluid warmers using coaxial warming tubes are superior in preventing heat loss. This laboratory investigation was performed in order to compare the heating capabilities of two coaxial fluid warmers.MethodsThe Hotline and the Autoline were investigated by using normal saline at various flow rates (10-99 ml x h(-1)). Final infusion temperatures were measured six times in a row at the end of the tubing by using a rapid-response thermometer. Final temperatures were compared with those of infusions, which passed through disposable i.v. tubing covered and warmed using an 'off label' convective air warming system (WarmTouch). Measurements were performed at two different room temperatures (20 and 24 degrees C). Each group was analyzed with respect to differences between various flow rates as well as differences between the groups at comparable flow rates by using a three-way anova with multiple comparisons according to Tukey's procedure. Significance was defined at P < 0.05.ResultsBoth devices heat infusions at low flow rates efficiently above 34 degrees C, with the Hotline being more effective than the Autoline (P < 0.0001). Except for the lowest flow rate (10 ml x h(-1)), the Hotline delivered infusion temperatures between 38 and 39 degrees C, while the Autoline warmed the infusions upto 36 degrees C. While heating capability of the Hotline was improved with elevated room temperatures at low flow rates (10-60 and 80 ml x h(-1)), the Autoline demonstrated lower infusion temperatures throughout elevated room temperature at flow rates between 20 and 90 ml x h(-1). Both devices heated infusions more efficiently compared with 'off label used' convective air warmer (each with P < 0.0001).ConclusionsBoth the Hotline and the Autoline heated infusions sufficiently at low flow rates. However, the heating capability of the Hotline was superior and can further be increased at low flow rates by increasing the room temperature.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.