    BackgroundThe purpose of this study was to evaluate the reliability of a new uncalibrated pulse contour method, the MostCare, in determining cardiac output (CO) in septic patients.MethodsThirty patients with septic shock admitted to an intensive care unit, receiving a norepinephrine infusion and requiring haemodynamic monitoring with a pulmonary artery catheter, were prospectively enrolled. Thermodilution measurements of CO (ThD-CO) were considered as the 'gold standard'. MostCare was connected to the monitoring system of the radial arterial pressure waveform to obtain a continuous CO calculation (MostCare-CO). ThD-CO and MostCare-CO measurements were recorded at three different haemodynamic states: baseline (T1), after raising mean arterial pressure (MAP) to 90 mm Hg by increasing the norepinephrine infusion (T2), and after returning the MAP to baseline value by decreasing vasopressor therapy (T3). A Bland-Altman and linear regression analyses were performed.ResultsA total of 90 paired ThD-CO and MostCare-CO measures were obtained (range 4.1-13.9 litre min(-1) for ThD-CO and 4.5-13.5 litre min(-1) for MostCare-CO). A good correlation between ThD-CO and MostCare-CO was observed (R = 0.93). The mean bias between the two techniques was -0.26 litre min(-1) (sd 0.98 litre min(-1)) and the 95% limits of agreement were -2.22 to 1.70 litre min(-1). The percentage of error was 25%. Pearson's R was 0.94, 0.92, and 0.93 at T1, T2, and T3, respectively.ConclusionsMostCare-CO and ThD-CO showed a good agreement at each time of the study. The reliability of the MostCare system was not affected by the vascular tone changes produced by a norepinephrine infusion.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…