• Anesthesia and analgesia · Feb 2011

    Measurement of dead space in subjects under general anesthesia using standard anesthesia equipment.

    • John J Badal, Kyung J Chen, and Robert G Loeb.
    • Department of Anesthesiology, University of Arizona, 1501 N. Campbell Ave., PO Box 245114, Tucson, AZ 85724-5114, USA. jjbadal@yahoo.com
    • Anesth. Analg. 2011 Feb 1;112(2):375-7.

    BackgroundPulmonary dead space is the volume of gas that is delivered to the lungs but does not participate in gas exchange. Knowing pulmonary dead space in patients under general anesthesia is clinically useful because it can aid in detecting disease processes such as pulmonary emboli or low cardiac output states. Dead space can be simply calculated by using the Bohr equation; however, it is difficult to measure mixed exhaled carbon dioxide (PECO(2)) with a standard anesthesia machine. Previously, a study at our institution demonstrated the carbon dioxide (CO(2)) concentration in the bellows of a standard anesthesia machine is an accurate approximation of PECO(2). In this study, we used the bellows PECO(2) measurement and arterial CO(2) (PaCO(2)) to calculate pulmonary dead space. We verified the technique by adding known apparatus dead space volumes during anesthesia.MethodsSubjects were under general endotracheal anesthesia. A sampling line was positioned inside the ventilator bellows and connected to a capnometer. Measurements of PECO(2) and PaCO(2) from an arterial catheter were taken at baseline and after adding 100 mL and 200 mL of dead space to the endotracheal tube. Dead space was calculated using the Bohr equation (alveolar dead space/tidal volume = [PaCO(2) - PECO(2)]/PaCO(2)) at baseline and after adding 100 mL and 200 mL of apparatus dead space.ResultsThe dead space at baseline was 265 ± 47 mL (mean ± SD) in 10 study subjects. After adding 100 mL of dead space to the endotracheal tube, the measured dead space increased by 110 ± 46 mL. The measured dead space increased by 158 ± 39 mL after adding 200 mL.ConclusionsOur baseline dead space measurements were in the expected range under general anesthesia. When dead space was added, we were able to calculate that an increase in dead space occurred. Our calculation was more accurate after adding a 100-mL volume than after adding 200 mL. We present a simple way to detect trends in dead space in ventilated patients using a Narkomed GS anesthesia machine (Dräger Medical, Lübeck, Germany).

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.