    Compliance of the respiratory system as a predictor for successful extubation in very-low-birth-weight infants recovering from respiratory distress syndrome.

    • J Smith, C H Pieper, D Maree, and R P Gie.
    • Department of Paediatrics and Child Health and Respiratory Technology, University of Stellenbosch, W Cape.
    • S. Afr. Med. J. 1999 Oct 1;89(10):1097-102.

    ObjectiveTo develop additional criteria to predict for successful extubation of very-low-birth-weight infants recovering from respiratory distress syndrome.DesignProspective study.SettingNeonatal intensive care unit at a university teaching hospital.InterventionsInfants ready for extubation according to clinical, ventilatory and blood gas criteria were studied. Before extubation, tidal volume (Vt), minute ventilation, respiratory rate/Vt and mean inspiratory flow were measured during two different ventilatory settings: (i) during intermittent mandatory ventilation (IMV); and (ii) while breathing spontaneously with endotracheal continuous positive airway pressure (CPAP). Tidal volume was obtained through electronically integrated flow measured by a hot-wire anemometer. Total respiratory compliance (Crs) was determined during IMV and was derived from the formula Vt/PIP-PEEP, where the difference between peak inspiratory pressure (PIP) and positive end-expiratory pressure (PEEP) represented the ventilator inflation pressure.Measurements And Main ResultsEach of 49 infants was studied once before extubation. 33 infants (67%) were successfully extubated and 16 (32.6%) required reintubation. Infants in the success and failure groups were matched for gestation, post-conceptional age, study weight and methylxanthine therapy at the time of study. Successful extubation was associated with a higher mean absolute Crs value (ml/cm H2O) specific Crs value (standardised for body length; ml/cm H2O/cm) compared with infants in whom extubation failed (0.67 v. 0.46; P = 0.01 and 0.018 v. 0.014; P = 0.03, respectively). Analysis of ROC curves detected thresholds for Crs (0.5 ml/cm H2O) and Vt (7 ml) for predicting successful extubation. An absolute Crs value 0.5 ml/cm H2O or more improved the likelihood of successful extubation when compared with clinical/ventilator and blood gas criteria. The likelihood of successful extubation was 81% if the Crs value was > or = 0.5 ml/cm H2O. A tidal volume of 7 ml or more was less sensitive in contributing to successful extubation (sensitivity 69%). The major causes for extubation failure included atelectasis (diffuse and/or localised) and the presence of a patent ductus arteriosus.ConclusionsIn addition to following very precise ventilatory criteria for extubation, we found that bedside measurement of total respiratory system compliance added to the likelihood of extubation success in infants recovering from respiratory distress syndrome. Prospective studies are needed to validate the findings of this study.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…