• Br J Anaesth · Feb 2013

    Relation between mixed venous oxygen saturation and cerebral oxygen saturation measured by absolute and relative near-infrared spectroscopy during off-pump coronary artery bypass grafting.

    • A Moerman, G Vandenplas, and T Bové.
    • Department of Anesthesiology, Ghent University Hospital, De Pintelaan 185, 9000 Ghent, Belgium. annelies.moerman@ugent.be
    • Br J Anaesth. 2013 Feb 1;110(2):258-65.

    BackgroundWe hypothesized that previously reported contradictory results regarding the equivalence of mixed venous (Smv(O(2))) and cerebral (rS(c)O(2)) oxygen saturation might be related to time delay issues and to measurement technology. In order to explore these two factors, we designed a prospective clinical study comparing with relative (INVOS(®)) and absolute (Foresight(®)) rS(c)O(2) measurements.MethodsForty-two consenting patients undergoing elective off-pump coronary artery bypass grafting were included. Two INVOS and two Foresight sensors continuously registered rS(c)O(2). Smv(O(2)) was measured continuously via a pulmonary artery catheter. Data were assessed by within- and between-group comparisons and correlation analysis.ResultsA similar time delay of 19 (4) and 18 (4) s was found for compared with rS(c)O(2) measurements by Foresight and INVOS, respectively, during haemodynamic changes. After adjusting for this time delay, the correlation between Smv(O(2)) and rS(c)O(2) increased from r=0.25 to 0.75 (P<0.001) for Foresight, and from r=0.28 to 0.73 (P<0.001) for INVOS. Comparison of Foresight and INVOS revealed significant differences in absolute rS(c)O(2) values (range 58-89% for Foresight and 28-95% for INVOS). Changes in rS(c)O(2) in response to acute haemodynamic alterations were significantly more pronounced with INVOS compared with Foresight (P<0.001).ConclusionsConsidering the important time delay with Smv(O(2)), rS(c)O(2) seems to reflect more appropriately acute haemodynamic alterations. This might suggest its use as a valid alternative to invasive monitoring of tissue oxygen saturation. Relative and absolute rS(c)O(2) measurements demonstrated significant differences in measured rS(c)O(2) values and in the magnitude of rS(c)O(2) changes during haemodynamic alterations.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.