• J Clin Monit Comput · Apr 1998

    Influence of pulse oximeter settings on the frequency of alarms and detection of hypoxemia: Theoretical effects of artifact rejection, alarm delay, averaging, median filtering or a lower setting of the alarm limit.

    • A T Rheineck-Leyssius and C J Kalkman.
    • Twenteborg Hospital, Almelo, The Netherlands. leyssius@knmg.nl
    • J Clin Monit Comput. 1998 Apr 1; 14 (3): 151-6.

    ObjectiveThe potential benefit of a reduced frequency of false pulse oximeter low oxyhemoglobin saturation (SpO2) alarms is that the attention of personnel is only directed to patients who experience hypoxemia. The present study was undertaken to better understand the effects of different settings of the pulse oximeter on false (artifact) and true (hypoxemia) alarms.MethodsUsing the original SpO2 data of 200 postoperative patients, we calculated off-line the effects of five methods (artifact rejection, alarm delay (2-44 s, 2 s increments), averaging (10-90 s), median filtering (10-90 s) and decreasing the alarm limit from 90% to 85%) on the number of (true- and false) alarms.Results830 episodes of hypoxemia (SpO2 < or = 90%) and 73 episodes of severe hypoxemia (SpO2 < or = 85%) occurred. With a SpO2 alarm limit of 90%, the alarm was triggered 1535 times (830 true, 705 false). Artifact rejection reduced alarms by almost 50%. An alarm delay of 6 s or an averaging or median filtering epoch of 10 s resulted in an alarm reduction of almost 50%. No differences were found in the reduction of alarms between averaging and median filtering. Changing the alarm limit to 85% reduced the number of alarms by 82%. A similar reduction of alarms was obtained with either an alarm delay of 18 s or an averaging or median filtering epoch of 42 s. However, an alarm limit of 85% reduced the number of false alarms less than the other three algorithms (p < 0.01).ConclusionsThe data from the present study suggest that in order to effectively suppress false alarms caused by pulse oximeter artifacts, it may be preferable to use a longer filtering epoch of approximately 40 s, rather than to decrease the lower alarm limit.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.