• Neurosurgery · Oct 2008

    Intraoperative neurophysiological monitoring in an open low-field magnetic resonance imaging system: clinical experience and technical considerations.

    • Andrea Szelényi, Thomas Gasser, and Volker Seifert.
    • Department of Neurosurgery, Johann Wolfgang Goethe University Hospital, Frankfurt, Germany. A.Szelenyi@em.uni-frankfurt.de
    • Neurosurgery. 2008 Oct 1;63(4 Suppl 2):268-75; discussion 275-6.

    ObjectiveThe intraoperative combination of an open magnetic resonance imaging (MRI) system with neurophysiological localization and continuous monitoring techniques allows for the best available anatomic and physiological orientation as well as real-time functional monitoring. Methodological aspects and technical adaptations for this combination of methods and the experience in 29 patients with tumors in the central region are reported.MethodsMRI-compatible platinum/iridium electrodes for intraoperative neuromonitoring were attached to the patient's head. All other electrodes located outside the magnet were stainless steel needle-electrodes for recording of motor evoked potentials and for stimulating somatosensory evoked potentials. Intraoperative MRI was performed using a 0.15-T intraoperative magnetic resonance scanner (PoleStar N20; Medtronic Surgical Navigation Technologies, Louisville, KY).ResultsThe calculated and measured values of the maximum induced magnetic field (2 x 10(-6) T), induced voltage (0.1 V), and force (0.01 N) by the static or changing magnetic field within all attached electrodes were negligible and proved the method's safety. In 29 patients, platinum/iridium electrodes with low susceptibility showed no interference with the imaging quality. Furthermore, neurophysiological monitoring could be performed with unaffected recording quality. Side effects (e.g., thermal induction) were not observed.ConclusionNeurophysiological monitoring for evoked potentials and direct cortical stimulation can be performed with standard quality within a low-field intraoperative MRI system. Electrodes fixed to the head should be of low magnetic susceptibility to guarantee optimal imaging quality. The combined use of an open ultra low-field MRI system and intraoperative monitoring allows for resection control and continuous functional monitoring.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.