• Can J Kidney Health Dis · Jan 2015

    Development of a hemodialysis safety checklist using a structured panel process.

    • Samuel A Silver, Alison Thomas, Andrea Rathe, Pamela Robinson, Ron Wald, Ziv Harel, and Chaim M Bell.
    • Division of Nephrology, St. Michael's Hospital, University of Toronto, Toronto, Canada.
    • Can J Kidney Health Dis. 2015 Jan 1;2:5.

    BackgroundThe World Health Organization created a Surgical Safety Checklist with a pause or "time out" to help reduce preventable adverse events and improve communication. A similar tool might improve patient safety and reduce treatment-associated morbidity in the hemodialysis unit.ObjectiveTo develop a Hemodialysis Safety Checklist (Hemo Pause) for daily use by nurses and patients.DesignA modified Delphi consensus technique based on the RAND method was used to evaluate and revise the checklist.SettingUniversity-affiliated in-center hemodialysis unit.ParticipantsA multidisciplinary team of physicians, nurses, and administrators developed the initial version of the Hemo Pause Checklist. The evaluation team consisted of 20 registered hemodialysis nurses.MeasurementsThe top 5 hemodialysis safety measures according to hemodialysis nurses. A 75% agreement threshold was required for consensus.MethodsThe structured panel process was iterative, consisting of a literature review to identify safety parameters, individual rating of each parameter by the panel of hemodialysis nurses, an in-person consensus meeting wherein the panel refined the parameters, and a final anonymous survey that assessed panel consensus.ResultsThe literature review produced 31 patient safety parameters. Individual review by panelists reduced the list to 25 parameters, followed by further reduction to 19 at the in-person consensus meeting. The final round of scoring yielded the following top 5 safety measures: 1) confirmation of patient identity, 2) measurement of pre-dialysis weight, 3) recognition and transcription of new medical orders, 4) confirmation of dialysate composition based on prescription, and 5) measurement of pre-dialysis blood pressure. Revision using human factors principles incorporated the 19 patient safety parameters with greater than or equal to 75% consensus into a final checklist of 17-items.LimitationsThe literature review was not systematic. This was a single-center study, and the panel lacked patient and family representation.ConclusionsA novel 17-item Hemodialysis Safety Checklist (Hemo Pause) for use by nurses and patients has been developed to standardize the hemodialysis procedure. Further quality improvement efforts are underway to explore the feasibility of using this checklist to reduce adverse events and strengthen the safety culture in the hemodialysis unit.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…