• Injury · Jul 2012

    CT scanogram for limb length discrepancy in comminuted femoral shaft fractures following IM nailing.

    • Rahul Vaidya, Brent Anderson, Ashraf Elbanna, Robert Colen, Daniel Hoard, and Anil Sethi.
    • Department of Orthopedics, Detroit Receiving Hospital, Detroit, MI 48201, USA.
    • Injury. 2012 Jul 1;43(7):1176-81.

    IntroductionLeg length discrepancy (LLD) following intramedullary nailing of femoral fractures is not uncommon. We designed a prospective study to evaluate the efficacy of routine postoperative computed tomography (CT) scanograms for evaluation of limb length discrepancy in patients with comminuted Winquist III or IV femoral shaft fractures treated with intramedullary nailing.MethodsThe study consisted of 15 patients with Winquist III and 13 with a Winquist IV femoral shaft fracture pattern with an average age of 37 years. The mechanisms of injury were motor vehicle collision (13), gunshot wound (12) and falls (three). All patients were treated with a statically locked intramedullary femoral nail (18 antegrade and 10 retrograde). A CT scanogram evaluated limb length in all patients. A discrepancy of greater than 20mm was considered for correction during the same admission. An LLD of 15-20mm was discussed with the patient extensively for correction.ResultsIn the 28 patients included in our study, the average limb length discrepancy was 9.1mm with a range of -43.5mm short to 10.3mm long. The LLD was less than 10mm in 18 patients (64%), 10-15mm in four patients (14%), 15-20mm in three patients (11%) and more than 20mm in three patients (11%). Measurement of discrepancy as small as 0.5mm showed that 18 patients were fixed with shortening and in 10 patients the operated femur was longer. Tibia lengths were also evaluated separately. Though none of the tibiae had a previous fracture, only three patients (10%) had tibiae of equal length. In 13 patients, an unequal tibia partially corrected the LLD whilst in 12 it added to the discrepancy. Five patients with LLD of greater than 15mm underwent correction.ConclusionsA postoperative scanogram in patients with comminuted femoral shaft fractures treated with intramedullary nailing is useful to evaluate LLD and allows for early intervention. The ideal length where correction is necessary remains unclear.Copyright © 2012 Elsevier Ltd. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.