• Chest · Oct 1994

    Comparative Study

    Efficacy of a new full face mask for noninvasive positive pressure ventilation.

    • G J Criner, J M Travaline, K J Brennan, and D T Kreimer.
    • Division of Pulmonary and Critical Care Medicine, Temple University School of Medicine, Philadelphia.
    • Chest. 1994 Oct 1;106(4):1109-15.

    AbstractPrevious studies have shown that noninvasive positive pressure ventilation (NPPV) improves gas exchange in acute and chronic respiratory failure. However, some patients are unable to tolerate NPPV due to air leaks around the mask, facial discomfort, and claustrophobia. A new mask that covers the entire face (Total, Respironics, Monroeville, Pa), attempts to overcome these obstacles. We studied the efficacy of NPPV via the Total face mask (TFM) in nine patients with chronic respiratory failure. In three patients, respiratory failure was due to chronic obstructive lung disease, and in six patients, it was secondary to restrictive disorders. None of the patients were previously able to tolerate NPPV via nasal (N) or nasal-oral (NO) masks. At baseline, all patients had impaired gas exchange with low PaO2/FIO2 (241 +/- 14), elevated PaCO2 (79 +/- 5 mm Hg), and poor functional status (1.89 +/- 1.45, on a scale of 1 to 7). After NPPV in the hospital for 7.1 +/- 1.5 h per night for 22 +/- 26 days, the PaCO2 fell to 59 +/- 3 mm Hg, and the PaO2/FIO2 rose to 304 +/- 27. Following nocturnal NPPV via the TFM for 6.7 +/- 1.5 h a night 6 +/- 5 weeks after hospital discharge, sustained improvements in PaCO2 (58 +/- 3 mm Hg, p < 0.05), PaO2/FIO2 (304 +/- 18), and functional status (5.38 +/- 1.06, p < 0.05) were observed. In four patients, measurements of respiratory rate, tidal volume, minute ventilation, dyspnea, discomfort with the face mask, and mask and mouth leaks were made during 30-min sessions of NPPV applied at constant levels via all three masks (N, NO, TFM). Discomfort with the face mask (0.38 +/- 0.18 vs 1.44 +/- 0.34 vs 2.38 +/- 0.32, p < 0.05) and mask leaks (0.44 +/- 0.18 vs 1.89 +/- 0.39 vs 1.89 +/- 0.35, p < 0.05) were least during NPPV via TFM compared with the N or NO masks, respectively. Moreover, expired tidal volume was highest (804 +/- 10 vs 498 +/- 9 vs 537 +/- 13 ml, p < 0.05) and PaCO2 lowest (51 +/- 2 vs 57 +/- 2 vs 58 +/- 3, p < 0.05) during NPPV via the TFM compared with N or NO masks. We conclude that NPPV delivered via a Total mask ensures a comfortable, stable patient-mask interface and improves gas exchange in selected patients intolerant of more conventional N or NO masks.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.