• Annals of surgery · Nov 2010

    Multicenter Study Clinical Trial

    Laparoscopic sphincter augmentation device eliminates reflux symptoms and normalizes esophageal acid exposure: one- and 2-year results of a feasibility trial.

    • Luigi Bonavina, Tom DeMeester, Paul Fockens, Daniel Dunn, Greta Saino, Davide Bona, John Lipham, Willem Bemelman, and Robert A Ganz.
    • Department of Surgery, University of Milano Medical School, IRCCS Policlinico San Donato, Milan, Italy. luigi.bonavina@unimi.it
    • Ann. Surg. 2010 Nov 1;252(5):857-62.

    ObjectivesOne- and 2-year evaluation of a feasibility trial (clinicaltrials.gov registration numbers NCT01057992, NCT01058070, and 01058564) to assess the safety and efficacy of a laparoscopically implanted sphincter augmentation device for the treatment of gastroesophageal reflux disease (GERD).MethodsA sphincter augmentation device (LINX Reflux Management System; Torax Medical, Shoreview, MN), designed to prevent reflux due to abnormal opening of the lower esophageal sphincter (LES), was laparoscopically implanted at the gastroesophageal junction in 44 patients. At baseline, all patients had abnormal esophageal acid exposure on 24-hour pH monitoring and improved, but persistent, typical GERD symptoms while on acid suppression therapy with proton pump inhibitors (PPIs). The device comprises a miniature string of interlinked titanium beads, with magnetic cores, placed around the gastroesophageal junction. The magnetic bond between adjacent beads augments sphincter competence. The beads temporarily separate to accommodate a swallowed bolus, allow belching or vomiting, and reapproximate to augment the LES in the closed position. Patients were evaluated after surgery by GERD Health-Related Quality of Life symptom score, PPI usage, endoscopy, esophageal manometry, and 24-hour esophageal pH monitoring.ResultsThe total mean GERD Health-Related Quality of Life symptom scores improved from a mean baseline value of 25.7 to 3.8 and 2.4 at 1- and 2-year follow-up, representing an 85% and 90% reduction, respectively (P < 0.0001). Complete cessation of PPI use was reported by 90% of patients at 1 year and by 86% of patients at 2 years. Early dysphagia occurred in 43% of the patients and self-resolved by 90 days. One device was laparoscopically explanted for persistent dysphagia without disruption of the anatomy or function of the cardia. There were no device migrations, erosions, or induced mucosal injuries. At 1 and 2 years, 77% and 90% of patients had a normal esophageal acid exposure. The mean percentage time pH was less than 4 decreased from a baseline of 11.9% to 3.1% (P < 0.0001) at 1 year and to 2.4% (P < 0.0001) at 2 years. Patient satisfaction was 87% at 1 year and 86% at 2 years.ConclusionsThe new laparoscopically implanted sphincter augmentation device eliminates GERD symptoms without creating undue side effects and is effective at 1 and 2 years of follow-up.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…