Comparative Study
Impact of different types of resuscitation fluids on coagulation and continuous venovenous hemofiltration hemocompatibility in a porcine model.
- Janis Rebecca Bedarf, Sascha Grosch-Ott, Martin Russ, Johanna Josophina Wagner, Bernhard Hiebl, Michael Kirschfink, and Juliane Katharina Unger.
- Department of Experimental Medicine (FEM), Charité-Universitätsmedizin Berlin, Berlin, Germany.
- Ther Apher Dial. 2013 Oct 1;17(5):510-23.
AbstractIntensive therapy demanding diseases (organ failure or sepsis) are assumed to be the etiology behind a decreased biocompatibility of extracorporeal systems for renal replacement therapy (RRT). There are also potential interactions between different components of the overall therapy. Volume substitutes are known to influence hemorheology and coagulation. To define a potential net effect of volume substitutes on the hemocompatibility of an RRT, we chose an animal model without interfering pathophysiologies. According to the problem of early filter failure and coagulation disorders in critically ill patients, we focused on the hypothesized interaction between RRT and different volume substitutes with respect to blood cell counts, coagulation parameters and required heparin dose. Forty-eight pigs were assigned to four groups of fluid therapy with either normal saline (NaCl), 6%HES130kD/0.4 (HES130), 6%HES200kD/0.5 (HES200) or 4%gelatin (GEL). Six pigs of each fluid group underwent continuous venovenous hemofiltration (CVVH), the remaining six served as the control group. Anticoagulation was performed with continuous heparin infusion. CVVH was run in a recirculation-mode for 4.5 h to force hemocompatibility reactions, thereafter in a standard-mode for 2 h. During the CVVH-treatment GEL reduced platelet counts and fibrinogen concentration and additionally lowered ATIII levels. Heparin requirements did not differ between different volume substitutes or CVVH and control groups. Severe pathophysiologies are not the only reason for a reduced hemocompatibility of CVVH treatment. Interaction of a particular volume substitute with CVVH should be considered when interpreting study results and evolving new strategies.© 2013 The Authors. Therapeutic Apheresis and Dialysis © 2013 International Society for Apheresis.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.