• Anesthesia and analgesia · Mar 2011

    Review Comparative Study

    A systematic review of third-generation hydroxyethyl starch (HES 130/0.4) in resuscitation: safety not adequately addressed.

    • Christiane S Hartog, Matthias Kohl, and Konrad Reinhart.
    • Department of Anesthesiology and Intensive Care Medicine, Jena University Hospital, Friedrich-Schiller University, Erlanger Allee 101, D-07747 Jena, Germany.
    • Anesth. Analg. 2011 Mar 1; 112 (3): 635-45.

    BackgroundHydroxyethyl starches (HES) are widely used for intravascular volume therapy in surgical, emergency, and intensive care patients. There are safety concerns with regard to coagulopathy, renal failure, pruritus, tissue storage, and mortality. Third-generation HES 130/0.4 is considered to have an improved risk profile. A common rationale for the use of HES is the belief that 3 to 4 times more crystalloid than colloid volume is needed to achieve similar hemodynamic end points. Our goal was to assess whether published studies on HES 130/0.4 resuscitation are sufficiently well designed to draw conclusions about the safety of this compound. In addition, we wanted to assess crystalloid-to-colloid fluid ratios in studies with goal-directed fluid regimen.MethodsSystematic review of randomized controlled trials in which HES 130/0.4 is used for resuscitation.ResultsWe identified 56 randomized controlled trials (RCTs) with HES 130/0.4 in. acute hypovolemia, mainly from the elective surgical setting (n = 45). Surgical studies were small-sized (median 25 patients in the HES groups, range 10 to 90) and of short duration (median 12 hours, range 0.5 to 144 hours). The median cumulative HES dose was 2465 mL (range 328 to 6229 mL), corresponding to 35 mL/kg in a 70-kg patient, the daily dose limit being 50 mL/kg. End points mostly addressed variable surrogate outcomes. Sixty percent of control fluids were other HES solutions, gelatins, or dextran, which have a similar risk profile. Without exception, these studies were not designed for clinically important safety outcomes, primarily because they were too small, used mostly inadequate control fluids, and had inappropriately short observation periods. Therefore, and also because of heterogeneity of patient groups and outcome definitions, results from these studies cannot be pooled. These studies do not allow any conclusion about the safety of HES 130/0.4. There is a common belief that 3 to 4 times more crystalloid than colloid volume is necessary to achieve similar hemodynamic effects. We found a considerably lower ratio in surgical studies (mean 1.8, SD 0.1).ConclusionsIn summary, the extent of fluid load reduction that can be achieved by HES 130/0.4 is overestimated. Use of older HES solutions may be associated with serious side effects, and clinicians should be aware that there is no convincing evidence that third-generation HES 130/0.4 is safe in surgical, emergency, or intensive care patients despite publication of numerous clinical studies.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.