• Acta Neurochir. Suppl. · Jan 1998

    Comparative Study

    Clinical evaluation of the Codman microsensor intracranial pressure monitoring system.

    • H M Fernandes, K Bingham, I R Chambers, and A D Mendelow.
    • Department of Neurosurgery, University of Newcastle-upon-Tyne, U.K.
    • Acta Neurochir. Suppl. 1998 Jan 1;71:44-6.

    IntroductionThe use of the Camino fibre-optic subdural device for measuring Intracranial Pressure (ICP) in patients, has been shown to correlate well with recordings from the "gold standard" intraventricular fluid filled catheter [1]. Following this work, its use has become standard in the clinical monitoring of patients. More recently, laboratory studies have demonstrated accuracy, acceptable drift and high fidelity for the new Codman Microsensor ICP Transducer, a miniature strain gauge mounted on a flexible nylon catheter [3]. Its performance in patients, however, has yet to be fully assessed, in comparative studies.MethodsEight patients (5 head injured, 3 with an Intracerebral haematoma) had a Codman Microsensor inserted. A Camino Transducer was fitted immediately adjacent to it. A computerised system was used to continuously record both ICP readings.ResultsIn total 140,323 recordings were made over a wide range of ICP values. Study periods ranged from 0.5 to 116 hours. In one patient the Codman transducer tracing failed after several days, probably due to fracture of electrical cable close to the interface box. The readings from the two ICP transducers were compared on Time Series, logistic regression and Altman-Bland plots. Drift of the ICP recorded by the Codman microsensor, was noted in 2 patients, 1 in positive direction (maximum 30 mmHg), 1 negative (max. 20 mmHg). In both cases the Camino ICP recording was relatively stable. In 24% of the recordings the Codman microsensor recorded ICP as 5 or more mmHg greater than the Camino, this difference was 10 mmHg or greater in 9% of recordings. Conversely the Camino recording was 5 mmHg or more, than the Codman, in 5% of all recordings, and 10 mmHg or more in 3%.ConclusionThese differences could in the majority of cases (excepting the negative drift) be explained by a constant offset of the Codman transducer, as described previously [6]. Further examination of this device is required.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.