Comparative Study
Clinical evaluation of intraparenchymal Spiegelberg pressure sensor.
- Josef-Michael Lang, Jürgen Beck, Michael Zimmermann, Volker Seifert, and Andreas Raabe.
- Department of Neurosurgery, Neurocenter, Johann Wolfgang Goethe University, Schleusenweg 2-16, 60528 Frankfurt am Main, Germany.
- Neurosurgery. 2003 Jun 1;52(6):1455-9; discussion 1459.
ObjectiveThe Spiegelberg 3-PN intraparenchymal pressure sensor was clinically evaluated.Description Of InstrumentationThe Spiegelberg intraparenchymal pressure sensor is a low-cost device that uniquely performs regular automatic zeroing in situ throughout the measurement period.Operative TechniqueThe Spiegelberg sensor was inserted in 87 patients who required intracranial pressure monitoring as part of their routine management. Complications were assessed by postoperative computed tomographic scanning and clinical investigation. The automated zeroing procedure was assessed after implantation of the sensor and during long-term measurement. In five patients, the "gold standard' of intraventricular pressure was measured simultaneously and compared with the intraparenchymal or subdural Spiegelberg 3-PN pressure.Experience And ResultsNo complications associated with the Spiegelberg sensor were observed. The duration of monitoring ranged from 3 to 28 days (mean, 10 d). In 3 patients, technical problems occurred, and in 84 patients, the pressure measurement was successful, including the automatic zeroing procedures performed by the monitor after insertion and hourly thereafter. The absolute difference between the Spiegelberg reading and the intraventricular pressure was less than +/-3 mm Hg in 99.6% and less than +/-2 mm Hg in 91.3% of readings. An Altman-Bland bias plot revealed good agreement between the two methods, with an average bias of 0.5 mm Hg, but revealed a significant trend toward 10% lower Spiegelberg readings with increasing intracranial pressure of >25 mm Hg. There was no difference between intraparenchymal and subdural locations.ConclusionThe Spiegelberg 3-PN sensor was reliable and simple to use. It can be recommended for routine intraparenchymal and subdural pressure measurement at a considerably lower price compared with other tip transducers and has the unique advantage of automated zeroing in vivo.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.