    Effect of pressure support on end-expiratory lung volume and lung diffusion for carbon monoxide.

    • Nathalina Pinto Da Costa, Fabiano Di Marco, Aissam Lyazidi, Guillaume Carteaux, Mourad Sarni, and Laurent Brochard.
    • Réanimation Médicale, AP-HP, Centre Hospitalier Albert Chenevier-Henri Mondor, INSERM Unité 955, Université Paris EST, Créteil, France. nathalia.pintodacosta@rdb.aphp.fr
    • Crit. Care Med.. 2011 Oct 1;39(10):2283-9.

    ObjectivesThe level of pressure-support ventilation can affect mean airway pressure and potentially lung volume, but its increase is usually associated with a reduced respiratory rate, and the net effects on the gas exchange process and its components, including end-expiratory lung volume, have not been carefully studied. We measured pulmonary conductance for gas exchange based on lung diffusion for carbon monoxide in patients receiving pressure-support ventilation.DesignProspective, randomized, crossover study.SettingMedical intensive care unit of a university hospital.PatientsSixteen patients mechanically ventilated in pressure-support ventilation mode and free from chronic obstructive pulmonary disease.InterventionsTwo pressure-support ventilation levels (5 cm H2O difference) at the same level of positive end-expiratory pressure.Measurements And Main ResultsEnd-expiratory lung volume, lung diffusion for carbon monoxide, and SpO2/Fio2 were evaluated. Increasing pressure-support ventilation by 5 cm H2O significantly increased the mean tidal volume from 6.8 to 8.5 mL/kg of predicted body weight and decreased the mean respiratory rate by 6.6 breaths per minute. Although SpO2/Fio2 did not change significantly, there was a slight but significant decrease in lung diffusion for carbon monoxide (average decay rate of 4.5%) at high pressure-support ventilation. The pressure-support ventilation level did not significantly affect end-expiratory lung volume (1737±629 mL at 9.6±2.5 cm H2O pressure-support ventilation level vs. 1749±657 mL at 14.9±2.1 cm H2O pressure-support ventilation level).ConclusionsA 5-cm H2O increase in pressure-support ventilation neither affected end-expiratory lung volume nor increased the pulmonary volume participating in gas exchange. A target tidal volume closer to 6 mL/kg of predicted body weight than to 8 mL/kg during pressure-support ventilation was associated with better gas exchange.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?

    User can't be blank.

    Content can't be blank.

    Content is too short (minimum is 15 characters).

    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…