-
Critical care medicine · Oct 2011
Comparative StudyComparisons of predictive performance of breathing pattern variability measured during T-piece, automatic tube compensation, and pressure support ventilation for weaning intensive care unit patients from mechanical ventilation.
- Mauo-Ying Bien, You Shui Lin, Chung-Hung Shih, You-Lan Yang, Hui-Wen Lin, Kuan-Jen Bai, Jia-Horng Wang, and Yu Ru Kou.
- School of Respiratory Therapy, Department of Physiology, Biostatistics and Research Consultion Center, and Division of Pulmonary Medicine, Taipei Medical University Hospital, and Institute of Physiology, National Yang-Ming University, Taipei, Taiwan.
- Crit. Care Med.. 2011 Oct 1;39(10):2253-62.
ObjectiveTo investigate the influence of different ventilatory supports on the predictive performance of breathing pattern variability for extubation outcomes in intensive care unit patients.Design And SettingA prospective measurement of retrospectively analyzed breathing pattern variability in a medical center.PatientsSixty-eight consecutive and ready-for-weaning patients were divided into success (n=45) and failure (n=23) groups based on their extubation outcomes.MeasurementsBreath-to-breath analyses of peak inspiratory flow, total breath duration, tidal volume, and rapid shallow breathing index were performed for three 30-min periods while patients randomly received T-piece, 100% inspiratory automatic tube compensation with 5 cm H2O positive end-expiratory pressure, and 5 cm H2O pressure support ventilation with 5 cm H2O positive end-expiratory pressure trials. Coefficient of variations and data dispersion (standard descriptor values SD1 and SD2 of the Poincaré plot) were analyzed to serve as breathing pattern variability indices.Main ResultsUnder all three trials, breathing pattern variability in extubation failure patients was smaller than in extubation success patients. Compared to the T-piece trial, 100% inspiratory automatic tube compensation with 5 cm H2O positive end-expiratory pressure and 5 cm H2O pressure support ventilation with 5 cm H2O positive end-expiratory pressure decreased the ability of certain breathing pattern variability indices to discriminate extubation success from extubation failure. The areas under the receiver operating characteristic curve of these breathing pattern variability indices were: T-piece (0.73-0.87)>100% inspiratory automatic tube compensation with 5 cm H2O positive end-expiratory pressure (0.60-0.79)>5 cm H2O pressure support ventilation with 5 cm H2O positive end-expiratory pressure (0.53-0.76). Analysis of the classification and regression tree indicated that during the T-piece trial, a SD1 of peak inspiratory flow>3.36 L/min defined a group including all extubation success patients. Conversely, the combination of a SD1 of peak inspiratory flow ≤3.36 L/min and a coefficient of variations of rapid shallow breathing index ≤0.23 defined a group of all extubation failure patients. The decision strategies using SD1 of peak inspiratory flow and coefficient of variations of rapid shallow breathing index measured during 100% inspiratory automatic tube compensation with 5 cm H2O positive end-expiratory pressure and 5 cm H2O pressure support ventilation with 5 cm H2O positive end-expiratory pressure trials achieved a less clear separation of extubation failure from extubation success.ConclusionsSince 100% inspiratory automatic tube compensation with 5 cm H2O positive end-expiratory pressure and 5 cm H2O pressure support ventilation with 5 cm H2O positive end-expiratory pressure reduce the predictive performance of breathing pattern variability, breathing pattern variability measurement during the T-piece trial is the best choice for predicting extubation outcome in intensive care unit patients patients.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.