• Critical care medicine · Sep 2011

    Heart-lung interactions measured by electrical impedance tomography.

    • Stefan Maisch, Stephan H Bohm, Josep Solà, Matthias S Goepfert, Jens C Kubitz, Hans Peter Richter, Jan Ridder, Alwin E Goetz, and Daniel A Reuter.
    • Department of Anesthesiology, Center of Anesthesiology and Intensive Care Medicine, Hamburg-Eppendorf, Germany.
    • Crit. Care Med.. 2011 Sep 1;39(9):2173-6.

    ObjectiveThe clinical value of stroke volume variations to assess intravascular fluid status in critically ill patients is well known. Electrical impedance tomography is a noninvasive monitoring technology that has been primarily used to assess ventilation. We investigated the potential of electrical impedance tomography to measure left ventricular stroke volume variation as an expression of heart-lung interactions. The objective of this study was thus to determine in a set of different hemodynamic conditions whether stroke volume variation measured by electrical impedance tomography correlates with those derived from an aortic ultrasonic flow probe and arterial pulse contour analysis.DesignProspective animal study.SettingUniversity animal research laboratory.SubjectsDomestic pigs, 29-50 kg.InterventionsA wide range of hemodynamic conditions were induced by mechanical ventilation at different levels of positive end-expiratory pressure (0-15 cm H₂O) and with tidal volumes of 8 and 16 mL/kg of body weight and by hypovolemia due to blood withdrawal with subsequent retransfusion followed by infusions of hydroxyethyl starch.Measurements And Main ResultsIn eight pigs, aortic stroke volume variations measured by electrical impedance tomography were measured and compared to those derived from an aortic ultrasonic flow probe and from arterial pulse contour analysis. Data for four animals were used to develop and train a novel frequency-domain electrical impedance tomography analysis algorithm, while data for the remaining four were used to test the performance of the novel methodology. Correlation of stroke volume variation measured by electrical impedance tomography and that derived from an aortic ultrasonic flow probe was significant (r = 0.69; p < .001), as was the correlation between stroke volume variation measured by electrical impedance tomography and that derived from arterial pulse contour analysis (r = 0.73; p < .001). Correlation of stroke volume variation derived from an aortic ultrasonic flow probe and that derived from arterial pulse contour analysis was significant too (r = 0.82; p < .001). Bland-Altman analysis comparing stroke volume variation measured by electrical impedance tomography and that derived from an aortic ultrasonic flow probe revealed an overall bias of 1.87% and limits of agreement of ± 7.02%; when comparing stroke volume variation measured by electrical impedance tomography and that derived from arterial pulse contour analysis, the overall bias was 0.49% and the limits of agreement were ± 5.85%.ConclusionStroke volume variation measured by electrical impedance tomography correlated with both the gold standard of direct aortic blood flow measurements of stroke volume variation and pulse contour analysis, marking an important step toward a completely noninvasive monitoring of heart-lung interactions.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…