• Biomed Instrum Technol · Nov 1991

    Noninvasive measurement of arterial oxyhemoglobin saturation with a heated and a non-heated skin reflectance pulse oximeter sensor.

    • Y Mendelson and B L Yocum.
    • Biomedical Engineering Department, Worcester Polytechnic Institute, Massachusetts 01609.
    • Biomed Instrum Technol. 1991 Nov 1;25(6):472-80.

    AbstractThe feasibility of measuring arterial oxyhemoglobin saturation (SaO2) noninvasively using a skin reflectance pulse oximeter sensor attached to the scalp, neck, and thigh regions of anesthetized swine was investigated. The optical reflectance sensor used consisted of a pair of red and infrared light-emitting diodes and a concentric array of six identical photodiodes. Two prototype sensor assemblies were evaluated: one assembly housed only the optical sensor, whereas the other also included a miniature heater. Measurements made from the scalp and neck regions were obtained with the non-heated skin reflectance sensor, and measurements from the thigh were made with the heated prototype. Each sensor was interfaced to a commercial transmittance pulse oximeter adapted to perform as a reflectance pulse oximeter. SaO2 values obtained by the reflectance pulse oximeters (SpO2(r) were compared simultaneously with SaO2 values obtained from arterial blood samples and analyzed in vitro with a CO-oximeter. The equations for the best-fitted linear regression lines describing the relationships between SpO2(r) and SaO2 values in the range between 30 and 100% were: SpO2(r) = 10.7 + 0.90 (SaO2), n = 321, r = 0.97; SpO2(r) = 16.72 + 0.82 (SaO2), n = 217, r = 0.95; and SpO2(r) = 20.21 + 0.77 (SaO2), n = 37, r = 0.97 for the neck, thigh, and scalp measurements, respectively. The regression analysis revealed significant correlation and a relatively small standard error of estimate (SEE = 4.05% for the neck, 4.79% for the thigh, and 3.50% for the scalp measurements). This study demonstrated the feasibility of measuring SaO2 noninvasively over a wide range of values utilizing the principle of reflectance pulse oximetry.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.