Biomed Instrum Technol · Nov 1991
Noninvasive measurement of arterial oxyhemoglobin saturation with a heated and a non-heated skin reflectance pulse oximeter sensor.
- Y Mendelson and B L Yocum.
- Biomedical Engineering Department, Worcester Polytechnic Institute, Massachusetts 01609.
- Biomed Instrum Technol. 1991 Nov 1;25(6):472-80.
AbstractThe feasibility of measuring arterial oxyhemoglobin saturation (SaO2) noninvasively using a skin reflectance pulse oximeter sensor attached to the scalp, neck, and thigh regions of anesthetized swine was investigated. The optical reflectance sensor used consisted of a pair of red and infrared light-emitting diodes and a concentric array of six identical photodiodes. Two prototype sensor assemblies were evaluated: one assembly housed only the optical sensor, whereas the other also included a miniature heater. Measurements made from the scalp and neck regions were obtained with the non-heated skin reflectance sensor, and measurements from the thigh were made with the heated prototype. Each sensor was interfaced to a commercial transmittance pulse oximeter adapted to perform as a reflectance pulse oximeter. SaO2 values obtained by the reflectance pulse oximeters (SpO2(r) were compared simultaneously with SaO2 values obtained from arterial blood samples and analyzed in vitro with a CO-oximeter. The equations for the best-fitted linear regression lines describing the relationships between SpO2(r) and SaO2 values in the range between 30 and 100% were: SpO2(r) = 10.7 + 0.90 (SaO2), n = 321, r = 0.97; SpO2(r) = 16.72 + 0.82 (SaO2), n = 217, r = 0.95; and SpO2(r) = 20.21 + 0.77 (SaO2), n = 37, r = 0.97 for the neck, thigh, and scalp measurements, respectively. The regression analysis revealed significant correlation and a relatively small standard error of estimate (SEE = 4.05% for the neck, 4.79% for the thigh, and 3.50% for the scalp measurements). This study demonstrated the feasibility of measuring SaO2 noninvasively over a wide range of values utilizing the principle of reflectance pulse oximetry.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.