• Am. J. Crit. Care · Nov 1995

    Comparative Study Clinical Trial Controlled Clinical Trial

    Comparison of continuous with intermittent bolus thermodilution cardiac output measurements.

    • C E Ditmyer, M Shively, D B Burns, and R T Reichman.
    • Palomar Medical Center, Escondido, Calif., USA.
    • Am. J. Crit. Care. 1995 Nov 1;4(6):460-5.

    BackgroundFew complete studies have been published to validate the agreement between continuous cardiac output and intermittent thermodilution cardiac output.ObjectiveTo analyze the agreement between cardiac output measurements by the continuous thermodilution method and the intermittent bolus thermodilution method, using a continuous cardiac output catheter in postoperative cardiothoracic surgery patients.MethodsA convenience sample of 14 adult cardiothoracic surgical patients with thermodilution pulmonary artery catheters placed preoperatively was used. A total of 214 comparison measurements of cardiac output by both the continuous and intermittent thermodilution methods were taken on patient admission to the critical care unit, every 4 hours, and with any change greater than 10% from baseline readings.ResultsThe intraclass correlation between continuous cardiac output and intermittent cardiac output was .89. The limits of agreement were -1.34 to 1.18 L/min, indicating that in 95% of readings the difference between continuous cardiac output and intermittent cardiac output were within this range.ConclusionsThe continuous cardiac output monitoring method shows clinically acceptable agreement with the intermittent cardiac output method.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…