Intensive care medicine · Jun 2011
Optimisation of positive end-expiratory pressure by forced oscillation technique in a lavage model of acute lung injury.
- Raffaele L Dellacà, Emanuela Zannin, Peter Kostic, Marie Andersson Olerud, Pasquale P Pompilio, Goran Hedenstierna, Antonio Pedotti, and Peter Frykholm.
- Dipartimento di Bioingegneria, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milan, Italy. raffaele.dellaca@polimi.it
- Intensive Care Med. 2011 Jun 1;37(6):1021-30.
PurposeWe evaluated whether oscillatory compliance (C(X5)) measured by forced oscillation technique (FOT) at 5 Hz may be useful for positive end-expiratory pressure (PEEP) optimisation.MethodsWe studied seven pigs in which lung injury was induced by broncho-alveolar lavage. The animals were ventilated in volume control mode with a tidal volume of 6 ml/kg. Forced oscillations were superimposed on the ventilation waveform for the assessment of respiratory mechanics. PEEP was increased from 0 to 24 cmH(2)O in steps of 4 cmH(2)O and subsequently decreased from 24 to 0 in steps of 2 cmH(2)O. At each 8-min step, a CT scan was acquired during an end-expiratory hold, and blood gas analysis was performed. C(X5) was monitored continuously, and data relative to the expiratory hold were selected and averaged for comparison with CT and oxygenation.ResultsOpen lung PEEP (PEEP(ol)) was defined as the level of PEEP corresponding to the maximum value of C(X5) on the decremental limb of the PEEP trial. PEEP(ol) was on average 13.4 (± 1.0) cmH(2)O. For higher levels of PEEP, there were no significant changes in the amount of non-aerated tissue (V(tissNA)%). In contrast, when PEEP was reduced below PEEP(ol), V(tissNA)% dramatically increased. PEEP(ol) was able to prevent a 5% drop in V(tissNA)% with 100% sensitivity and 92% specificity. At PEEP(ol) V(tissNA)% was significantly lower than at the corresponding PEEP level on the incremental limb.ConclusionsThe assessment of C(X5) allowed the definition of PEEP(ol) to be in agreement with CT data. Thus, FOT measurements of C(X5) may provide a non-invasive bedside tool for PEEP titration.© Copyright jointly held by Springer and ESICM 2011
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*,_underline_or**bold**. - Superscript can be denoted by
<sup>text</sup>and subscript<sub>text</sub>. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3., hyphens-or asterisks*. - Links can be included with:
[my link to pubmed](http://pubmed.com) - Images can be included with:
 - For footnotes use
[^1](This is a footnote.)inline. - Or use an inline reference
[^1]to refer to a longer footnote elseweher in the document[^1]: This is a long footnote..