-
- Athanase D Protogerou, Antonis Argyris, Efthymia Nasothimiou, Dimitris Vrachatis, Theodoros G Papaioannou, Dimitris Tzamouranis, Jacques Blacher, Michel E Safar, Petros Sfikakis, and George S Stergiou.
- Hypertension Center and Cardiovascular Research Laboratory, 1st Department of Propaedeutic Medicine, Laiko Hospital, National and Kapodistrian University of Athens, Athens, Greece. aprotog@med.uoa.gr
- Am. J. Hypertens. 2012 Aug 1;25(8):876-82.
BackgroundAccumulating evidence suggests the potential superiority of office aortic blood pressure (BP) over brachial in the management of arterial hypertension. The noninvasive aortic 24-h ambulatory brachial BP monitoring (ABPM) is potentially the optimal method for assessing BP profile. The objective of the present study was to investigate the feasibility and reproducibility to perform noninvasively 24-h aortic ABPM with a novel validated brachial cuff-based automatic oscillometric device (Mobilo-O-Graph) which records brachial BP and waveforms and assesses aortic BP via mathematical transformation.MethodsThirty consecutive subjects (mean age: 53.6 ± 11.6 years, 17 men) had a test-retest ABPM with at least 1-week interval. No modification of vasoactive drug treatment during the interval was allowed while similar 24-h activity during both recording days was recommended.ResultsThe average number of valid readings for brachial vs. aortic BP were 69.9 ± 10.4 vs. 58.0 ± 13.3 in the initial 24-h assessment (P < 0.001) and 68.3 ± 10.8 vs. 56.4 ± 13.6 in the repeat assessment (P < 0.001). No differences in average 24 h aortic BP values were observed between the two assessments (systolic blood pressure (SBP) 115.9 ± 7.7 vs. 115.1 ± 6.0 mm Hg, respectively, P = 0.48, and diastolic 79.7 ± 7.4 vs. 79.2 ± 8.7, P = 0.54). Reproducibility indices of aortic pressure including, intraclass coefficient of variation (SBP: 0.80 (95% confidence interval 0.58-0.90); diastolic: 0.92 (0.83-0.96)) and s.d. of differences (SBP/diastolic: 6.0/4.5 mm Hg) indicated acceptable reproducibility. The Bland-Altman plots indicated no evidence of systemic bias.ConclusionsIn conclusion, these data suggest that noninvasive 24-h ABPM is feasible and provides reproducible values. Future studies should validate the prognostic ability of 24-h aortic hemodynamics.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.