Critical care medicine · May 2006
Comparative StudyComparison of a single indicator and gravimetric technique for estimation of extravascular lung water in endotoxemic pigs.
- Patrik Rossi, Michael Wanecek, Anders Rudehill, David Konrad, Eddie Weitzberg, and Anders Oldner.
- Department of Physiology and Pharmacology, Section of Anaesthesiology & Intensive Care Medicine, Karolinska Institute, Stockholm, Sweden.
- Crit. Care Med. 2006 May 1;34(5):1437-43.
ObjectivesTo compare the single thermal indicator dilution (STID) technique for measurement of extravascular lung water (EVLW(STID)) with gravimetrically determined EVLW (EVLW(GRAV)) in anesthetized pigs under sham and endotoxemic conditions.DesignOpen experimental comparative animal study.SettingUniversity animal research laboratory.SubjectsFifteen anesthetized landrace pigs.InterventionsEndotoxin infusion during 5 hrs in five pigs. Six animals were only anesthetized and rested for 5 hrs. In four additional animals, the impact on EVLW(STID) measurements by changes in pulmonary perfusion, ventilation, and the combination of the two was studied. The alterations in ventilation and perfusion were induced by caval balloon inflation, inflation of the pulmonary artery catheter balloon, and bronchial plugging respectively.Measurements And Main ResultsThe STID technique, with default settings of the intrathoracic blood volume (ITBV) to global end-diastolic volume (GEDV) (i.e., the extrapulmonary intravascular volume between the point of injection of the indicator, and the point of detection) relationship (ITBV = 1.25GEDV), systematically overestimated the EVLW index compared with the gravimetrical method (mean bias of 5.4 mL/kg). By adapting the ITBV to GEDV relationship to the current model (ITBV = 1.52GEDV + 49.7), the accuracy of the STID technique improved. Moreover, the measurement of EVLW(STID) proved to be reduced by manipulation of pulmonary perfusion and ventilation. However, the STID technique could detect an increase in EVLW during endotoxemia independent of the ITBV/GEDV relationship used.ConclusionDespite technological improvement, the dilution techniques for the measurement of EVLW might still be influenced by changes in perfusion and ventilation. The STID technique, in addition, might demand adjustment of the ITBV/GEDV relationship to the particular condition and species subjected to measurement. The STID technique may, however, be a useful tool for monitoring changes of EVLW over time, but further studies are warranted to confirm this.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.