Comparative Study Clinical Trial
Relative blood volume measurements during hemodialysis: comparisons between three noninvasive devices.
- Judith J Dasselaar, Roel M Huisman, Paul E DE Jong, and Casper F M Franssen.
- Dialysis Center Groningen, Division of Nephrology, University Medical Center Groningen and University of Groningen, Groningen, The Netherlands.
- Hemodial Int. 2007 Oct 1;11(4):448-55.
AbstractThe monitoring of relative blood volume changes (DeltaRBV) has been advocated for the prevention of hemodialysis (HD) hypotension. Stand-alone devices (Crit-Line) or devices incorporated into the HD apparatus (blood volume monitor [BVM], Hemoscan) are widely used for this purpose. Comparisons between devices are scarce. The aim of this study was, first, to compare DeltaRBV results from these 3 devices with DeltaRBV calculated from changes in laboratory-derived hemoglobin (DeltaRBV-lab-Hb) and, second, to compare DeltaRBV results between the different devices. Fourteen patients received 2 HD treatments in a randomized order: one with the Hemoscan and Crit-Line combination and one with the BVM and Crit-Line combination. DeltaRBV-lab-Hb was measured at 2 and 4 hr into the HD session. Bland-Altman analyses showed that DeltaRBV results from the 3 devices differed systematically from DeltaRBV-lab-Hb, i.e., the difference between the 3 devices and DeltaRBV-lab-Hb varied significantly (p<0.05) with the magnitude of the measurement. The interdevice comparison showed considerable differences in DeltaRBV results. At the end of the treatment, a significant difference (p<0.05) between DeltaRBV measured by the Hemoscan and Crit-Line device (-9.8+/-2.7% and -11.5+/-4%, respectively) was found. In most patients, a systematic difference between Crit-Line and Hemoscan and between Crit-Line and BVM was observed. Relative blood volume change measurements by Crit-Line, Hemoscan, and BVM yield results that differ systematically from the results obtained from laboratory-derived Hb changes. Furthermore, there are substantial differences in DeltaRBV results between the 3 DeltaRBV devices.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.