• Internal medicine · Jan 2012

    Comparative Study

    Comparison between the apnea-hypopnea indices determined by the REMstar Auto M series and those determined by standard in-laboratory polysomnography in patients with obstructive sleep apnea.

    • Yukiko Ikeda, Takatoshi Kasai, Fusae Kawana, Satoshi Kasagi, Hisashi Takaya, Sugao Ishiwata, and Koji Narui.
    • Sleep Center, Toranomon Hospital, Japan.
    • Intern. Med. 2012 Jan 1;51(20):2877-85.

    ObjectiveContinuous positive airway pressure (CPAP) is an effective treatment for obstructive sleep apnea (OSA). After performing an initial titration study, most physicians do not have the CPAP equipment retitrated unless the patient complains about the CPAP use. Several automated CPAP devices are used clinically that can detect upper airway obstructive events and provide information about residual events while patients are on CPAP. The aim of this study was to compare the apnea-hypopnea index (AHI) determined by automated CPAP devices to that obtained from polysomnography.MethodsPatients with OSA underwent polysomnography for CPAP titration using the REMstar Auto M-series. The initial two hours of CPAP titration were spent at a subtherapeutic pressure of 4 cmH(2)O so that more breathing events could be observed. The correlations between the simultaneous determination of the AHI with polysomnography (AHI-PSG) and the automated device (AHI-RAM) during the subtherapeutic, therapeutic and overall phases were evaluated. In addition, the apnea index (AI) and the hypopnea index (HI) were each evaluated separately.ResultsSixty patients were enrolled. The mean AHI on diagnostic PSG was 35.2±2.6 events/hour. Strong correlations were observed between the AHI-PSG and the AHI-RAM (subtherapeutic: r=0.958, p<0.001; therapeutic: r=0.824, p<0.001; overall: r=0.927, p<0.001). A slightly stronger correlation was observed between the AI values, whereas a weaker correlation was observed between the HI values in all three phases.ConclusionStrong correlations between the AHI-PSG and the AHI-RAM were observed. The correlations were weakened when the analysis was limited to the HI and the therapeutic phase.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…