• Anesthesia and analgesia · Aug 2013

    Noninvasive continuous cardiac output by the nexfin before and after preload-modifying maneuvers: a comparison with intermittent thermodilution cardiac output.

    • Serban Ion Bubenek-Turconi, Mihaela Craciun, Ion Miclea, and Azriel Perel.
    • 1-st Department of Cardiovascular Anaesthesiology and Intensive Care, Prof. C. C. Iliescu Institute for Cardiovascular Diseases, Bucharest, Romania. bubenek@alsys.ro
    • Anesth. Analg.. 2013 Aug 1;117(2):366-72.

    BackgroundThe Nexfin uses an uncalibrated pulse contour method for the continuous measurement of cardiac output (CO) in a totally noninvasive manner. Since the accuracy of pulse contour methods and their ability to track changes in CO have been repeatedly questioned, we have compared the CO measured by the Nexfin (NAPCO) with the CO measured by the pulmonary artery catheter (PACCO) in cardiosurgical patients before and after preload-modifying maneuvers.MethodsTwenty-eight patients who underwent on-pump cardiac surgery, of whom 18 were receiving vasopressor and/or inotropic therapy, were studied during the first postoperative hours. Preload modification, in the form of either a fluid challenge or a passive leg raising maneuver, was done whenever clinically indicated, with PACCO and NAPCO being simultaneously measured before and after each intervention.ResultsA fluid challenge was administered to 22 patients, and the passive leg raising maneuver was performed in 6 patients. These interventions were repeated in 19 patients producing a total of 47 pairs of measurements. At baseline, mean (±SD) CO was 4.9 ± 1.1 and 5.0 ± 1.4 L·min(-1), for the PACCO and NAPCO, respectively, bias 0.1 ± 1.0, 95% prediction interval -2.5 to 2.4 L·min(-1), and 39% of error. After preload modification, the mean CO was 5.6 ± 1.3 and 5.6± 1.5 L·min(-1) for the PACCO and NAPCO, respectively, bias -0.0 ± 1.1, 95% prediction interval -2.6 to 2.7 L·min(-1), and 38% of error. The correlation coefficients (r) between the PACCO and NAPCO before and after preload modification were 0.71 (95% confidence interval [95% CI], 0.53-0.82) and 0.70 (95% CI, 0.52-0.82), respectively. Preload modification induced similar absolute changes in PACCO and NAPCO (r = 0.9, P < 0.0001). A 4-quadrant scatter plot showed a concordance rate of 100% (95% CI, 80.5%-100%) between the changes in NAPCO and PACCO. Polar plot analysis demonstrated a small polar angle and radial limits of agreement well below the 30° benchmark. The area under a receiver operating characteristic curve, testing the ability of Nexfin to detect an increase of ≥15% in PACCO, was 0.974 (95% CI, 0.93-0.99).ConclusionsAlthough the Nexfin has limited accuracy when compared with the pulmonary artery catheter, it can reliably track preload-induced changes in CO in stable patients after cardiac surgery in the presence of moderate vasopressor and inotropic therapy. This ability, combined with its total noninvasiveness, fast installation, and ease of use, make the Nexfin a suitable monitor for the perioperative continuous measurement of CO. The reliability of this monitor in tracking the CO when significant changes in peripheral resistance take place still needs to be established.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.