    BackgroundIt is generally accepted that when an ignition source is used the inspired oxygen concentration (FIO2) should be <30% in the breathing circuit to help prevent airway fires. The time and conditions required to reduce a high O2% in the breathing circuit to <30% has not yet been systematically studied.MethodsWe evaluated the inspired and expired circuit oxygen concentration response times of an Aestiva Avance S/5 anesthesia machine to reach an FIO2 of <30% from a starting FIO2 of 100% and 60% after reducing the FIO2 to 21%. The circuit was connected to a human patient simulator which has a functional residual capacity of 2 L, total lung capacity of 2.8 L, an oxygen consumption of 200 mL/min, and respiratory quotient of 0.8. Fresh gas flow (FGF) inputs of 2 L/min and 5 L/min were chosen to represent a spectrum of typical clinical FGF rates. Minute ventilation was set at 4 L/min. Determining the requisite median time to reach an O2 concentration of <30% in the breathing circuit was the primary aim of the study.ResultsThe median times (1st-99th percent confidence interval) required to achieve inspiratory and expiratory oxygen concentrations of <30% with the extended circuit configuration when starting at 60% for 5 L FGFs were 35 (32-36) and 104 (88-122) seconds, respectively. With 2 L FGF, these median times increased to 303 (291-313) and 255 (232-278) seconds, respectively. A shortened circuit configuration (P = 0.006) and higher FGF flow rate (P < 0.0001) were noted to be factors decreasing the median time required to achieve an oxygen concentration of <30%.ConclusionsBoth inspired and expired circuit oxygen concentration may take minutes to decrease to <30% depending on circuit length, FGF rate, and starting circuit oxygen concentration. During the reduction in FIO2, the expiratory oxygen concentration may be >30% for a considerable time after the FIO2 is in a "safe" range. An increased expired oxygen concentration should also be considered an airway fire risk, and patient care protocols may need to be modified based on future studies.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.