• J Clin Monit Comput · Apr 2014

    Oxygenation advisor recommends appropriate positive end expiratory pressure and FIO2 settings: retrospective validation study.

    • Michael J Banner, Neil R Euliano, and David Grooms.
    • Department of Anesthesiology, University of Florida College of Medicine, PO Box 100254, 1600 SW Archer Road, Gainesville, FL, 32610, USA, mbanner@anest.ufl.edu.
    • J Clin Monit Comput. 2014 Apr 1;28(2):203-10.

    AbstractA decision support, rule-based oxygenation advisor that provides guidance for setting positive end expiratory pressure (PEEP) and fractional inhaled oxygen concentration (FIO2) for patients with respiratory failure is described. The target oxygenation goal is to achieve and maintain pulse oximeter oxygen saturation (SpO2) ≥ 88 and ≤ 95%, as posited by the Acute Respiratory Distress Syndrome Network, by recommending appropriate combinations of PEEP and FIO2. For patient safety, the oxygenation advisor monitors mean arterial blood pressure (MAP) to ensure it is ≥ 65 mmHg for hemodynamic stability and inspiratory plateau pressure (Pplt) so it is ≤ 30 cm H2O for lung protection. The purpose of this validation study was to compare attending physicians' recommendations to those recommendations of the oxygenation advisor for setting PEEP and FIO2. Adults with respiratory failure (n = 117) receiving ventilatory support were studied. PEEP, FIO2, SpO2, MAP, and Pplt are input variables into the advisor. Recommendations to increase, maintain, or decrease PEEP and FIO2 are the oxygenation advisor's output variables. Physicians' recommendations for setting PEEP and FIO2 were recorded; the oxygenation advisor's recommendations were also recorded for comparison. At all times, ventilator settings were based on recommendations from attending physicians. PEEP ranged from 2 to 22 cm H2O and FIO2 ranged from 0.30 to 0.65. A total of 326 recommendations by the oxygenation advisor and attending physicians were made to increase, maintain, or decrease PEEP and FIO2. There was a very significant relationship (p < 0.0001) between recommendations of the oxygenation advisor and attending physicians for setting PEEP and FIO2. The agreement rate for recommendations by the oxygenation advisor and attending physicians was 92%. The K statistic, a test of the strength of agreement of recommendations between the oxygenation advisor and attending physicians, was 0.82 (p < 0.0001), indicating "almost perfect agreement". Relationships for recommendations made by the oxygenation advisor and attending physicians for setting PEEP and FIO2 were excellent, PEEP: r = 0.98 (p < 0.01), r(2) = 0.96; FIO2: r = 0.91 (p < 0.01), r(2) = 0.83, bias and precision values were negligible. A novel oxygenation advisor provided continuous and automatic recommendations for setting PEEP and FIO2 that were shown to be as good as the clinical judgment of experienced attending physicians. For all patients, the target oxygenation goal was achieved. Concerning patient safety, the oxygenation advisor detected those occasions when MAP and Pplt were in potentially unsafe ranges.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…