• Anesthesia and analgesia · Oct 2000

    Comparative Study

    Defining segments and phases of a time capnogram.

    • K Bhavani-Shankar and J H Philip.
    • Department of Anesthesiology, Perioperative, and Pain Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts 02115, USA. Bhavani@capnography.com
    • Anesth. Analg. 2000 Oct 1;91(4):973-7.

    UnlabelledThe division of a time capnogram into inspiratory and expiratory segments is arbitrary and results in the inability of a time capnogram to detect rebreathing instantaneously. Demarcation of a time capnogram into inspiratory and expiratory components using gas flow signals will not only facilitate prompt detection of rebreathing, but will also allow application of standardized and physiologically appropriate nomenclature for better understanding and interpretation of time capnograms. A Novametrix((R)) CO(2)-SMO plus respiratory profile monitor (Novametrix Medical Systems, Wallingford, CT) was used to obtain a simultaneous display of CO(2) and respiratory flow waveforms on a computer screen during spontaneous and controlled ventilation using a circle system with the inspiratory valve competent (no rebreathing) and with the valve displaced (rebreathing). Because the response time of the CO(2) analyzer was similar to the response time of the flow sensor, a comparison was made between the two waveforms to determine the inspiratory segment (Phase 0) and the expiratory segment of the time capnogram and its subdivisions (Phases I, II, and III). The end of expiration almost coincides with the downslope of the CO(2) waveform in the capnograms when there is no rebreathing. However, in the presence of rebreathing, the alveolar plateau is prolonged and includes a part of inspiration (Phase 0), in addition to the expiratory alveolar plateau (Phase III).ImplicationsPresently, the division of a time capnogram into inspiratory and expiratory segments is arbitrary. Demarcation of a time capnogram into various components using the gas flow signals facilitates prompt detection of the cause of abnormal capnograms that can widen the scope of future clinical applications of time capnography.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.