• Br J Anaesth · Apr 2014

    Case Reports

    Bone cement embolism attached to central venous catheter.

    • W Schummer, O Schlonski, and M Breuer.
    • Clinic for Anaesthesiology and Intensive Care Medicine, Friedrich Schiller University Jena, Erlanger Allee 103, Jena 07747, Germany.
    • Br J Anaesth. 2014 Apr 1;112(4):672-4.

    AbstractWe report on a rare complication of poly(methyl methacrylate) (PMMA), injected into the spine, which then inadvertently leaked into the venous system. This resulted in an embolism of PMMA and produced a mass surrounding a triple lumen central venous catheter located in the superior vena cava. The catheter as well as the attached mass of PMMA was retrieved safely by cardiothoracic surgery. This case emphasizes the importance of prompt diagnosis and treatment and illustrates the need for close monitoring of patients undergoing any spinal surgery that includes vertebroplasty.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…