    [Application of transcutaneous electrical nerve stimulation to multimodal analgesia after total knee arthroplasty].

    • Quan Zhang, Jian-Hua Zhang, and Pei-Jian Tong.
    • Zhongguo Gu Shang. 2014 Apr 1;27(4):283-6.

    ObjectiveTo study the effects of transcutaneous electrical nerve stimulation on multimodal analgesia after total knee arthroplasty.MethodsSixty patients diagnosed as knee osteoarthritis and suffered unilateral total knee arthroplasty in the department of orthopedics, Zhejiang Traditional Chinese Medicine Hospital from March 2009 to May 2012 were randomly divided into control group and test group, 30 cases in each group. All the patients received celecoxib preoperatively, knee periarticular injection with the drug mixture intraoperatively, and celecoxib and morphine sulfate controlled-release tablets postoperatively. The patients in the test group were also treated with transcutaneous electrical nerve stimulation each day after operation. All the patients started doing functional exercises at 24 h after operation. Postoperative visual analogue scales(VAS), passive and active range of motion of knee joint,and complications were recorded.ResultsThe VAS scores of test group during postoperative 24 h to 1 week were 3.39 +/- 0.69, 2.79 +/- 0.51, 2.16 +/- 0.52, and 1.07 +/- 0.57 separately,which were lower than 3.80 +/- 0.86, 3.22 +/- 0.58, 2.53 +/- 0.54 and 1.38 +/- 0.52 in the control group. The passive and active range of knee joint motion in the test group during postoperative 24 h to 2 weeks were (30.67 +/- 3.65) degrees, (39.17 +/- 3.96) degrees, (47.83 +/- 4.86) degrees, (93.67 +/- 7.30) degrees, (107.67 +/- 7.51) degrees and (29.83 +/- 5.33) degrees, (78.33 +/- 8.24) degrees, (95.17 +/- 5.94) degrees respectively,which were higher than (28.67 +/- 3.92) degrees, (36.83 +/- 4.25) degrees, (45.17 +/- 5.17) degrees, (89.83 +/- 7.25) degrees, (103.17 +/- 7.37) degrees and (24.17 +/- 10.26) degrees, (73.83 +/- 9.07) degrees, (91.33 +/- 7.42) degrees in the control group. In the test group, 19 patients had ring-shaped haemostasis impression to some extent in the skin of knee joint to different degree, and 5 patients had blister formation.ConclusionIt is meaningful to apply transcutaneous electrical nerve stimulation for treating multimodal analgesia after total knee arthroplasty,which can not only relieve patients' postoperative pain, and also promote the rehabilitation of knee function as far as possible.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.