• Anesthesia and analgesia · Mar 2014

    Randomized Controlled Trial Observational Study

    The effectiveness of cricoid pressure for occluding the esophageal entrance in anesthetized and paralyzed patients: an experimental and observational glidescope study.

    Cricoid pressure of 30N prevented the passage of both small and large gastric tubes into the oesophageal entrance, which the authors believe supports the utility of cricoid pressure in successfully occluding the oesophagus.

    summary
    • Ahed M Zeidan, M Ramez Salem, Jean-Xavier Mazoit, Mohamad Ali Abdullah, Tharwat Ghattas, and George J Crystal.
    • From the *Department of Anesthesiology, Procare Riaya Hospital, Al-Khobar, Kingdom of Saudi Arabia; †Department of Anesthesiology, Lebanese University, Beirut, Lebanon; ‡Department of Anesthesiology, Advocate Illinois Masonic Medical Center; §Department of Anesthesiology, University of Illinois College of Medicine, Chicago, Illinois; ‖Laboratoire d'Anesthésie, INSERM UMR788, Université Paris-Sud; ¶Département d'Anesthésie-Réanimation, Hôpitaux Universitaires Paris-Sud, AP-HP, Le Kremlin Bicêtre, France; and #Department of Anesthesiology, Tanta University Hospital, Egypt.
    • Anesth. Analg. 2014 Mar 1; 118 (3): 580-6.

    BackgroundIn the last 2 decades, the effectiveness of cricoid pressure (CP) in occluding the esophageal entrance has been questioned. Recent magnetic resonance imaging studies yielded conflicting conclusions. We used real-time visual and mechanical means to assess the patency of the esophageal entrance with and without CP in anesthetized and paralyzed adult patients.MethodsOne hundred seven, nonobese ASA physical status I and II patients were recruited for the study. A cricoid force of 30 N was used. This force was standardized by using a weighing scale before application of CP in each patient. After oxygen administration, anesthetic induction, neuromuscular blockade, and establishment of manual ventilation with FIO2 = 1.0, the view of the glottis and esophageal entrance was visualized, and video recordings were obtained by using a Glidescope video laryngoscope. Attempts to insert 2 gastric tubes (GTs), size 12 and 20 F, into the esophagus were made by a "blinded" operator without and with CP, the timing of which was randomized. A successful insertion of a GT in the presence of CP was considered evidence of a patent esophageal entrance (ineffective CP), whereas an unsuccessful insertion of a GT was considered evidence of an occluded esophageal entrance (effective CP). After the attempts to insert the GTs were completed, tracheal intubation was performed while CP was applied. The position of the esophageal entrance in relation to the glottis (midline versus lateral) was assessed from the video recordings, with and without CP.ResultsWe stopped the study when 79 patients (41 men and 38 women) qualified for and completed the study (2-sided Clopper-Pearson confidence interval (CI) 95% to 100%, n = 72). Advancement of either size GT into the esophagus could not be accomplished during CP in any patient but was easily done in all subjects when CP was not applied. This occurred whether the esophageal entrance was in a midline position or in a left or right lateral position relative to the glottis. Esophageal patency was visually observed in the absence of CP, whereas occlusion of the esophageal entrance was observed during CP in all patients. Without CP, the esophageal entrance was in a left lateral position in relation to the glottis in 57% ([95 % CI, 45%-68%)] of patients, at midline in 32% (CI, 22%-43%), and in a right lateral position in 11% (CI, 5%-21%). The position did not change with CP.ConclusionsThe current study provides additional visual and mechanical evidence supporting a success rate of at least 95% by using a cricoid force of 30 N to occlude the esophageal entrance in anesthetized and paralyzed normal adult patients. The efficacy of the maneuver was independent of the position of the esophageal entrance relative to the glottis, whether midline or lateral.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    This article appears in the collection: General Stuff.

    Notes

    comment
    1

    Of course the issue here is whether occlusion of the oesophageal entrance sufficient to prevent antegrade passage of a flexible silicon tube is a valid surrogate for the ability to prevent retrograde passage of liquid (ie. gastric fluid). There is a significant difference here and I feel this research adds little to the debate regarding benefit (or not) of cricoid pressure.

    Daniel Jolley  Daniel Jolley
    summary
    1

    Cricoid pressure of 30N prevented the passage of both small and large gastric tubes into the oesophageal entrance, which the authors believe supports the utility of cricoid pressure in successfully occluding the oesophagus.

    Daniel Jolley  Daniel Jolley
     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.