-
Anesthesia and analgesia · Jun 2008
Does patient position influence Doppler signal quality from the USCOM ultrasonic cardiac output monitor?
- Lyndon Siu, Adam Tucker, Shashi Kanth Manikappa, and John Monagle.
- Department of Anaesthesia, Monash Medical Centre, 246 Clayton Rd, Clayton, Victoria, Australia. lysiu@yahoo.com
- Anesth. Analg. 2008 Jun 1;106(6):1798-802.
BackgroundThe USCOM1A continuous wave cardiac output monitor (USCOM Pty Ltd., Sydney, NSW, Australia) is a novel Doppler-based device used to measure cardiac output noninvasively. The proper alignment of the transducer, and hence the ultrasound beam to the aortic or pulmonary outflow tracts, is essential to acquire accurate measurements and often much time is spent on transducer and/or patient positioning. In this prospective, observational, crossover study, we investigated the effect of patient positioning on the acquisition of cardiac output measurement with USCOM1A.MethodsWe measured cardiac output using USCOM1A in 30 healthy adult volunteers, each in five different positions: sitting, supine, Trendelenburg (20 degrees), left lateral tilt (20 degrees), and right lateral tilt (20 degrees) and compared the time required to obtain acceptable measurements. We also compared the quality of the Doppler signal obtained in these positions using a scoring system designed for this study.ResultsThere was a higher rate of failed measurement, the mean time to obtain the first acceptable measurement was prolonged and the optimal measurement obtained within a 5-min period was of a lower quality in the sitting position compared with the other four positions.ConclusionsOur results suggested the sitting position is the least suitable and least reliable position in which to perform cardiac output measurements using USCOM1A compared with the supine, Trendelenburg (20 degrees), left lateral tilt (20 degrees), and right lateral tilt (20 degrees) positions.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.