• Eur J Anaesthesiol · Aug 2004

    Clinical Trial

    Abnormalities of contrast sensitivity and electroretinogram following sevoflurane anaesthesia.

    • G Iohom, C Gardiner, A Whyte, G O'Connor, and G Shorten.
    • Cork University Hospital and University College Cork, Department of Anaesthesia and Intensive Care Medicine, Cork, Ireland.
    • Eur J Anaesthesiol. 2004 Aug 1;21(8):646-52.

    Background And ObjectiveWe tested the hypothesis that disturbances of the visual pathway following sevoflurane general anaesthesia (a) exist and persist even after clinical discharge criteria have been met and (b) are associated with decreased contrast sensitivity.MethodsWe performed pattern and full-field flash electroretinograms (ERG) in 10 unpremedicated ASA I patients who underwent nitrous oxide/sevoflurane anaesthesia. ERG and contrast sensitivity were recorded preoperatively, immediately after discharge from the recovery room and 2 h after discontinuation of sevoflurane. The time at which the Post Anaesthesia Discharge Score first exceeded 9 was also noted. Data were analysed using paired, one-tailed t-tests and Pearson's correlation coefficient.ResultsOn the full-field photopic ERG, b-wave latency was greater at each postoperative time point (31.6+/-1.1 and 30.8+/-1.1 ms) compared to preoperatively (30.1+/-1.1 ms, P < 0.001 and P = 0.03, respectively). Oscillatory potential latencies were greater on discharge from the recovery room compared with preanaesthetic values (23.1+/-3.1 vs. 22.4+/-3.3 ms, P = 0.01) and returned to baseline by 2 h after emergence from anaesthesia. Also at 2 h after emergence from anaesthesia: (a) P50 latency on the pattern ERG was greater than at baseline (81.5+/-17.9 vs. 51.15+/-22.6ms, P = 0.004); (b) N95 amplitude was less compared to preanaesthetic values (2.6+/-0.5 vs. 3.3+/-0.4 microV, P = 0.003) and (c) contrast sensitivity was less compared to baseline values (349+/-153 vs. 404+/-140, P = 0.048). A positive correlation was demonstrated between contrast sensitivity and both N95 amplitude and b-wave latency (r = 0.99 and r = -0.55 at significance levels of P < 0.005 and P < 0.05, respectively).ConclusionsPostoperative ERG abnormalities and associated decreases in contrast sensitivity are consistently present in patients who have undergone nitrous oxide/sevoflurane anaesthesia. These abnormalities persist beyond the time at which standard clinical discharge criteria have been met.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…