• Vet. Res. Commun. · Jan 1988

    A critical assessment of pulmonary function testing in exercising ponies.

    • T Art and P Lekeux.
    • Laboratory for Cardio-Pulmonary Functional Investigation, Faculty of Veterinary Medicine, University of Liege, Brussels, Belgium.
    • Vet. Res. Commun. 1988 Jan 1;12(1):25-39.

    AbstractPulmonary function measurements during exercise were tested for accuracy and reproducibility in 5 saddle ponies weighing 267 +/- 9 Kg. Airflow (V) and tidal volume (VT) were measured with a Fleisch pneumotachograph mounted on a face mask. The linearity of the response and the symmetry of this device were carefully checked. Pleural pressure changes were measured by pleural puncture (Ppl) and with an esophageal balloon catheter (Pes). The elastance of the esophageal wall and the effect of the position of the esophageal catheter tip on Pes were also investigated. Airflow, VT, Ppl, Pes, mask pressure, an electrocardiogram and limb movements were simultaneously recorded before, during and after exercise. These recordings were used to assess the validity of some pulmonary function measurements and to evaluate the influence of the breathing apparatus on the respiratory pattern. Maximal intrathoracic pressure changes and total pulmonary resistance values did not differ significantly when calculated on the basis of the Ppl and the Pes curves respectively. Although the absolute Ppl values were significantly different from the absolute Pes values, both pressures recorded at different workloads were closely correlated (R = 0.99). The mean specific elastance of the esophagus was 1.56 +/- 0.24 kPa.cm.ml.-1. Changes in the position of the esophageal catheter tip induced significant differences in the recorded Pes values. The pressure/flow relationship of the pneumotachograph pressure transducer system was linear within the range of the V measured during exercise. The mask had a significant influence on respiratory frequency and maximum difference in Pes, but did not modify the exercise-induced changes in these parameters. It was concluded that the technique and methods used in this study can allow accurate pulmonary function measurements in exercising ponies.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…