• Ann. Thorac. Surg. · Oct 2004

    Comparative Study

    Intraaortic balloon pumping improves hemodynamics and right ventricular efficiency in acute ischemic right ventricular failure.

    • Dag Nordhaug, Tor Steensrud, Stig Muller, Kjell Vidar Husnes, and Truls Myrmel.
    • Department of Cardiothoracic and Vascular Surgery, University Hospital North Norway, Tromsø, Norway. dagn@fagmed.uit.no
    • Ann. Thorac. Surg. 2004 Oct 1;78(4):1426-32.

    BackgroundLeft ventricular unloading has a potentially deleterious effect in right ventricular failure as a result of altered septal interplay. However, a positive effect of an intraaortic balloon pump during right ventricular failure has been suggested. We investigated the impact of intraaortic balloon pumping on hemodynamics and both left and right ventricular function in an experimental model of isolated right ventricular failure.MethodsSixteen anesthetized pigs (25 to 34 kg) were used in an in vivo model. Pressure-conductance catheters assessed right and left ventricular pressure-volume relationships. Acute right ventricular failure was induced by right coronary microembolization, and led to severely impaired right ventricular function, reduced cardiac output and arterial pressure, and an increased pulmonary vascular resistance and pulmonary arterial elastance. Animals were then randomized to balloon pump or control groups and evaluated with respect to hemodynamics and ventricular function after 1 hour.ResultsIntraaortic balloon pumping did not alter right or left ventricular contractility. However, balloon pump-treated animals had significantly improved cardiac output (+18% +/- 18% versus -6% +/- 7%; p = 0.003) and mean arterial pressure (+36% +/- 30% versus -7% +/- 14%; p = 0.004) compared with controls. Animals in the balloon pump group had lower pulmonary vascular resistance (795 +/- 63 versus 912 +/- 259 dynes . sec . cm(-5); p < 0.01) and pulmonary arterial elastance (1.14 +/- 0.20 versus 1.69 +/- 0.65 mm Hg/mL; p < 0.01), and increased stroke volume (22.3 +/- 4.7 versus 17.9 +/- 4.7 mL; p = 0.016). Right ventricular efficiency was also improved in the balloon pump group (stroke work per pressure-volume area = 0.60 +/- 0.14 versus 0.41 +/- 0.12; p < 0.01).ConclusionsIntraaortic balloon pump support does not alter right or left ventricular function in acute right ventricular failure. However, arterial pressure, cardiac output, and right ventricular efficiency are improved, possibly because of a balloon pump-induced reduction in pulmonary arterial resistance.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…