• J. Vasc. Surg. · May 2012

    Multicenter Study

    Cyber medicine enables remote neuromonitoring during aortic surgery.

    • Andreas Greiner, Werner H Mess, Juerg Schmidli, Eike S Debus, Jochen Grommes, Florian Dick, and Michael J Jacobs.
    • European Vascular Center Aachen-Maastricht, Department of Vascular Surgery, University Hospital Rheinisch-Westfälische Technische Hochschule Aachen, Aachen, Germany.
    • J. Vasc. Surg. 2012 May 1;55(5):1227-32; discussion 1232-3.

    ObjectiveThis study assessed the feasibility and effectiveness of remote neuromonitoring as an adjunct to spinal cord protection during surgical repair of descending thoracic aortic aneurysms and thoracoabdominal aortic aneurysms.MethodsFour aortic centers in three European countries participated in this prospective observational study. A similar surgical protocol was used in all centers, including assessment of spinal cord function by means of monitoring motor-evoked potentials (MEPs). MEP information was evaluated at one central neurophysiologic department in Maastricht, The Netherlands. Transfer of MEP data from all operating rooms to Maastricht was arranged by Internet connections. In all patients, the protective and surgical strategies to prevent paraplegia were based on MEPs. The on-site surgeons reacted in real time to the interpretation and feedback of the neurophysiologist.ResultsBetween March 2009 and May 2011, 130 patients (85 men) were treated by open surgical repair. Extent of aneurysms was equally distributed among the centers. Neuromonitoring was technically stabile and successful in all patients. The transfer of data from the operating room in the different vascular centers was undisturbed and without any technical problems. By maintaining a mean distal aortic pressure of 60 mm Hg, MEPs were undisturbed in 65 patients (50%). In another 65 patients (50%), significant changes in MEPs prompted the surgical teams to initiate additional protective and surgical strategies to restore spinal cord perfusion. These measures were not effective in five patients (3.8%), and acute paraplegia resulted. Delayed paraplegia occurred in 10 patients (7.7%) but improved in three and recovered completely in another three. No false-negative or false-positive MEP recordings were experienced.ConclusionsRemote neuromonitoring of spinal cord function during open repair of descending thoracic aortic aneurysms and thoracoabdominal aortic aneurysms as a telemedicine technique is feasible and effective. It allows centralization of expertise and saves individual centers from investing in complex technology. The value of monitoring MEPs was confirmed in different aortic centers, resulting in adequate neurologic outcome after extensive aortic surgical procedures.Copyright © 2012 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…