• Journal of biomechanics · Nov 1996

    Appropriately placed surface EMG electrodes reflect deep muscle activity (psoas, quadratus lumborum, abdominal wall) in the lumbar spine.

    • S McGill, D Juker, and P Kropf.
    • Department of Kinesiology, University of Waterloo, Canada.
    • J Biomech. 1996 Nov 1;29(11):1503-7.

    AbstractThis study tested the possibility of obtaining the activity of deeper muscles in the torso-specifically psoas, quadratus lumborum, external oblique, internal oblique and transverse abdominis, using surface myoelectric electrodes. It was hypothesized that: (1) surface electrodes adequately represent the amplitude of deep muscles (specifically psoas, quadratus lumborum, external oblique, internal oblique, transverse abdominis); (2) a single surface electrode location would best represent the activation profiles of each deep muscle over a broad variety of tasks. We assumed that prediction of activation within 10% of maximum voluntary contraction (RMS difference between the surface and intramuscular channels), over the time history of the signal, was reasonable and acceptable to assist clinical interpretation of muscle activation amplitude, and ultimately for modeled estimates of muscle force. Surface electrodes were applied and intramuscular electrodes were inserted on the left side of the body in five men and three women who then performed a wide variety of flexor tasks (bent knee and straight leg situps and leg raises, curl ups), extensor tasks (including lifting barbells up to 70 kg), lateral bending tasks (standing lateral bend and horizontal lying side support), twisting tasks (standing and sitting), and internal/external hip rotation. Using the criteria of RMS difference and the coefficient of determination (R2) to compare surface with intramuscular myoelectric signals, the results indicated that selected surface electrodes adequately represent the amplitude of deep muscles-always within 15% RMS difference, or less with the exception of psoas where differences up to 20% were observed but only in certain maximum voluntary contraction efforts. It appears reasonable for spine modelers, and particularly clinicians, to assume well selected surface electrode locations provide a representation of these deeper muscles-as long as they recognize the magnitude of error for their particular application.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.