    [Fluid-modulated RF ablation: in-vitro experiments].

    • P Bruners, M Hodenius, R W Günther, T Schmitz-Rode, and A Mahnken.
    • Lehrstuhl für Angewandte Medizintechnik, Helmholtz-Institut für Biomedizinische Technik, Aachen. bruners@hia.rwth-aachen.de
    • Rofo. 2007 Apr 1;179(4):380-6.

    PurposeTo evaluate the potential of different fluids to enhance the effect of radiofrequency ablation.Materials And MethodsA bipolar radiofrequency system with an internally cooled needle electrode was used to heat three samples of 16 different fluids. Each sample had a volume of 20 ml. The generator output was set to 20 watt as recommended by the vendor. Energy was applied until the temperature of the sample reached 80 degrees C or the duration of heating exceeded 30 minutes. If a fluid was not able to be heated because the resistance was too high, 15 ml of the fluid were mixed with 5 ml of a 1-mol saline solution. During energy deposition, the temperature was measured every 15 seconds. The applied energy, impedance, resistance, voltage and flowing current were recorded continuously.ResultsThe ionic contrast agent Telebrix Gastro was heated to 80 degrees C within 620 +/- 95 seconds which was the shortest time needed. It was not possible to heat the contrast agents Solutrast 300, Isovist 240, Gadovist and Lipiodol as well as a 40 % glucose solution and 95 % ethanol. The longest time was needed to heat the 40 % glucose solution + the 1-mol saline solution (1755 +/- 26 seconds). The correlation coefficients (Pearson) showed only a marginal connection between resistance and maximum temperature (r=0.52) and duration for heating up to 80 degrees C, respectively (r=- 0.54). The same is true for the connection between impedance and maximum temperature (r=0.52) as well as duration for heating up to 80 degrees C (r=- 0.57).ConclusionThe selection of an appropriate fluid allows an increase in the effect of radiofrequency ablation or the generation of a protective effect. Especially HAES, Magnevist and Telebrix Gastro are suitable for enhancing heating. Glucose solution or non-ionic contrast agents could be used to generate a protective effect during radiofrequency ablation. The heating of fluids by means of a bipolar radiofrequency ablation system is not only influenced by the electric properties but also by other parameters such as the specific heat capacity.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.