    BackgroundHeart failure with preserved ejection fraction (HFPEF) is a common, globally recognised, form of heart failure for which no treatment has yet been shown to improve symptoms or prognosis. The pathophysiology of HFPEF is complex but characterised by increased left atrial pressure, especially during exertion, which might be a key therapeutic target. The rationale for the present study was that a mechanical approach to reducing left atrial pressure might be effective in HFPEF.MethodsThe REDUCe Elevated Left Atrial Pressure in Patients with Heart Failure (REDUCE LAP-HF) study was an open-label, single-arm, phase 1 study designed to assess the performance and safety of a transcatheter interatrial shunt device (IASD, Corvia Medical, Tewkesbury, MA, USA) in patients older than 40 years of age with symptoms of HFPEF despite pharmacological therapy, left ventricular ejection fraction higher than 40%, and a raised pulmonary capillary wedge pressure at rest (>15 mm Hg) or during exercise (>25 mm Hg). The study was done at 21 centres (all departments of cardiology in the UK, Netherlands, Belgium, France, Germany, Austria, Denmark, Australia, and New Zealand). The co-primary endpoints were the safety and performance of the IASD at 6 months, together with measures of clinical efficacy, including functional capacity and clinical status, analysed per protocol. This study is registered with ClinicalTrials.gov, number NCT01913613.FindingsBetween Feb 8, 2014, and June 10, 2015, 68 eligible patients were entered into the study. IASD placement was successful in 64 patients and seemed to be safe and well tolerated; no patient had a peri-procedural or major adverse cardiac or cerebrovascular event or need for cardiac surgical intervention for device-related complications during 6 months of follow-up. At 6 months, 31 (52%) of 60 patients had a reduction in pulmonary capillary wedge pressure at rest, 34 (58%) of 59 had a lower pulmonary capillary wedge pressure during exertion, and 23 (39%) of 59 fulfilled both these criteria. Mean exercise pulmonary capillary wedge pressure was lower at 6 months than at baseline, both at 20 watts workload (mean 32 mm Hg [SD 8] at baseline vs 29 mm Hg [9] at 6 months, p=0·0124) and at peak exercise (34 mm Hg [8] vs 32 [8], p=0·0255), despite increased mean exercise duration (baseline vs 6 months: 7·3 min [SD 3·1] vs 8·2 min [3·4], p=0·03). Sustained device patency at 6 months was confirmed by left-to-right shunting (pulmonary/systemic flow ratio: 1·06 [SD 0·32] at baseline vs 1·27 [0·20] at 6 months, p=0·0004).InterpretationImplantation of an interatrial shunt device is feasible, seems to be safe, reduces left atrial pressure during exercise, and could be a new strategy for the management of HFPEF. The effectiveness of IASD compared with existing treatment for patients with HFPEF requires validation in a randomised controlled trial.FundingCorvia Medical Inc.Copyright © 2016 Elsevier Ltd. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…