Randomized Controlled Trial Comparative Study
Second-generation everolimus-eluting and paclitaxel-eluting stents in real-life practice (COMPARE): a randomised trial.
- Elvin Kedhi, Kaiyum Sheik Joesoef, Eugene McFadden, Jochem Wassing, Carlos van Mieghem, Dick Goedhart, and Pieter Cornelis Smits.
- Department of Cardiology, Maasstad Ziekenhuis, Rotterdam, Netherlands.
- Lancet. 2010 Jan 16;375(9710):201-9.
BackgroundEverolimus-eluting and paclitaxel-eluting stents, compared with bare metal stents, reduced the risk of restenosis in clinical trials with strict inclusion and exclusion criteria. We compared the safety and efficacy of the second-generation everolimus-eluting and paclitaxel-eluting stents in real-life practice.MethodsWe randomly assigned 1800 consecutive patients (aged 18-85 years) undergoing percutaneous coronary intervention at one centre to treatment with everolimus-eluting or paclitaxel-eluting stents. The primary endpoint was a composite of safety and efficacy (all-cause mortality, myocardial infarction, and target vessel revascularisation) within 12 months. Patients were not told which stent they had been allocated. Analysis was by intention to treat. The trial is registered with ClinicalTrials.gov, number NCT01016041.FindingsFollow-up was completed in 1797 patients. The primary endpoint occurred in 56 (6%) of 897 patients in the everolimus-eluting stent group versus 82 (9%) of 903 in the paclitaxel-eluting stent group (relative risk 0.69 [95% CI 0.50-0.95], p value for superiority=0.02). The difference was attributable to a lower rate of stent thrombosis (6 [<1%] vs 23 [3%], 0.26 [0.11-0-64], p=0.002), myocardial infarction (25 [3%] vs 48 [5%], 0.52 [0.33-0.84], p=0.007), and target vessel revascularisation (21 [2%] vs 54 [6%], 0.39 [0.24-0.64], p=0.0001). Cardiac death, non-fatal myocardial infarction, or target lesion revascularisation occurred in 44 [5%] patients in the everolimus-eluting stent group versus 74 [8%] patients in the paclitaxel-eluting stent group, p value for superiority was 0.005.InterpretationThe everolimus-eluting stent is better than the second generation paclitaxel-eluting stent in unselected patients in terms of safety and efficacy. On the basis of our results, we suggest that paclitaxel-eluting stents should no longer be used in everyday clinical practice.FundingUnrestricted grants from Abbott Vascular and Boston Scientific.Copyright 2010 Elsevier Ltd. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.