Pediatric dentistry · Mar 2000
Randomized Controlled Trial Clinical TrialMonitoring pediatric dental patients with nasal mask capnography.
- R E Primosch, I M Buzzi, and G Jerrell.
- University of Florida, College of Dentistry, Department of Pediatric Dentistry, Gainesville. rprimosch@dental.ufl.edu
- Pediatr Dent. 2000 Mar 1;22(2):120-4.
PurposeThe purpose of this study was to evaluate the potential of using capnography to analyze respiratory samples taken from a scavenging nitrous oxide nasal hood during routine pediatric dental procedures.MethodsTwenty-two subjects, aged 60-116 months, were administered alternately either 40% nitrous oxide/60% oxygen or 100% oxygen during two sequential restorative appointments. All subjects were monitored continuously for end-tidal carbon dioxide and respiratory rate using a capnograph whose sampling line was attached directly to the nitrous oxide nasal hood. The subject's breath sound, displayed behavior, type of dental procedure being performed, and presence of rubber dam isolation were recorded every minute throughout the two appointments.ResultsValues for end-tidal carbon dioxide and respiratory rate were displayed on the capnograph when administering either oxygen or a combination of nitrous oxide/oxygen inhalation through the nasal hood. These respiratory values were lowered significantly when comparing 40% nitrous oxygen-60% oxygen to 100% oxygen inhalation. They were not significantly altered by the type of breath sound, patient behavior, dental procedure, or presence of rubber dam isolation, with the exception of some dental procedures which significantly lowered end-tidal carbon dioxide. The apnea alarm on the capnograph occurred during 5% of the total treatment time, but its occurrence represented a 97% false positive rate. The occurrence of the apnea alarm was significantly associated with the type for breath sound, patient behavior, and dental procedure. When used in this manner, the capnograph was effective in alerting the practitioner to potential apneic events, but likely has limited value in monitoring valid end-tidal carbon dioxide levels due to limitations in the sampling technique.ConclusionsThis study demonstrated the potential of the capnograph as a respiratory monitor for pediatric dental patients when the sampling line was attached to a scavenging nitrous oxide nasal hood.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.