• Journal of neurosurgery · Jan 2010

    First intraoperative, shared-resource, ultrahigh-field 3-Tesla magnetic resonance imaging system and its application in low-grade glioma resection.

    • M Necmettin Pamir, Koray Ozduman, Alp Dinçer, Erdem Yildiz, Selçuk Peker, and M Memet Ozek.
    • Department of Neurosurgery, Acibadem University, School of Medicine, Istanbul, Turkey.
    • J. Neurosurg. 2010 Jan 1; 112 (1): 57-69.

    ObjectThe authors describe the first shared-resource, 3-T intraoperative MR (ioMR) imaging system and analyze its impact on low-grade glioma (LGG) resection with an emphasis on the use of intraoperative proton MR spectroscopy.MethodsThe Acibadem University ioMR imaging facility houses a 3-T Siemens Trio system and consists of interconnected but independent MR imaging and surgical suites. Neurosurgery is performed using regular ferromagnetic equipment, and a patient can be transferred to the ioMR imaging system within 1.5 minutes by using a floating table. The ioMR imaging protocol takes < 10 minutes including the transfer, and the authors obtain very high-resolution T2-weighted MR images without the use of intravenous contrast. Functional sequences are performed when needed. A new 5-pin headrest-head coil combination and floating transfer table were specifically designed for this system.ResultsSince the facility became operational in June 2004, 56 LGG resections have been performed using ioMR imaging, and > 19,000 outpatient MR imaging procedures have been conducted. First-look MR imaging studies led to further resection attempts in 37.5% of cases as well as a 32.3% increase in the number of gross-total resections. Intraoperative ultrasonography detected 16% of the tumor remnants. Intraoperative proton MR spectroscopy and diffusion weighted MR imaging were used to differentiate residual tumor tissue from peritumoral parenchymal changes. Functional and diffusion tensor MR imaging sequences were used both pre- and postoperatively but not intraoperatively. No infections or other procedure-related complications were encountered.ConclusionsThis novel, shared-resource, ultrahigh-field, 3-T ioMR imaging system is a cost-effective means of affording a highly capable ioMR imaging system and increases the efficiency of LGG resections.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…