-
Minerva anestesiologica · Sep 2015
Review Meta Analysis Comparative StudyColloids versus crystalloids in the prevention of hypotension induced by spinal anesthesia in elective cesarean section. a systematic review and meta-analysis.
- J Ripollés Melchor, Á Espinosa, E Martínez Hurtado, R Casans Francés, R Navarro Pérez, A Abad Gurumeta, and J M Calvo Vecino.
- Department of Anesthesia, Computense University of Madrid, Hospital Universitario Infanta Leonor, Madrid, Spain - ripo542@gmail.com.
- Minerva Anestesiol. 2015 Sep 1; 81 (9): 1019-30.
AbstractThe incidence of hypotension associated to spinal anesthesia in elective cesarean section is high. To determine the effects of colloids and crystalloids in the incidence of hypotension induced by spinal anesthesia in elective cesarean section, an attempt was made to define which type of fluid and what total volume should be administered. Following the PRISMA methodology a systematic review and meta-analysis were carried out. A systematic Medline/PubMed, EMBASE and Cochrane Library search was made to identify trials where women were scheduled for elective cesarean section with spinal anesthesia and volume loading (preload or co-load). The primary outcome was the incidence of hypotension. Stratification into subgroups was made for the primary outcome according to the type of colloid administered, differentiating those studies employing new generation colloids (HES 6% 130/0.4) from those not using such colloids, based on the volume of colloid administered and the combination of a vasopressor. The secondary outcome was the incidence of intraoperative nausea and vomiting. Two-hundred and twenty-seven controlled clinical trials were analyzed; eleven randomized clinical trials including 990 patients were included. A significative decrease of incidence of hypotension associated to spinal anesthesia was observed with the use of colloids compared to crystalloids (RR [95% CI] 0.70 [0.53-0.92], P=0.01). However, there was no difference between crystalloid and colloid in the risk of intraoperative nausea and vomiting (RR [95% CI] 0.75 [0.41-1.38]; P=0.33). This meta-analysis shows colloid administration to significantly reduce the incidence of hypotension associated to spinal anesthesia in elective cesarean section compared with of crystalloid use.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.