• Anesthesia and analgesia · Dec 2002

    Comparative Study

    The detection of changes in heparin activity in the rabbit: a comparison of anti-xa activity, thrombelastography, activated partial thromboplastin time, and activated coagulation time.

    • Vance G Nielsen.
    • Department of Anesthesiology (Divisions of Cardiothoracic Anesthesia and Anesthesiology Research), The University of Alabama at Birmingham, 35249, USA. vance.nielsen@ccc.uab.edu
    • Anesth. Analg. 2002 Dec 1; 95 (6): 1503-6, table of contents.

    UnlabelledThrombelastography (TEG) has been used to detect both exogenous and endogenous circulating heparin activity in clinical and laboratory settings. Thus, in this study I sought to compare the sensitivity of TEG, activated partial thromboplastin time (aPTT), and activated coagulation time (ACT) values with changes in anti-Xa activity after small-dose heparin administration in rabbits. Conscious rabbits (n = 11) had blood obtained from ear arteries for hematological analyses after the administration of 0, 10, 20, and 30 U/kg of IV heparin. Anti-Xa activities after the administration of 0, 10, 20, and 30 U/kg of heparin were, respectively, 38 +/- 9 mU/mL, 74 +/- 15 mU/mL, 105 +/- 14 mU/mL, and 134 +/- 17 mU/mL; all values were significantly different from each other. TEG variables (R and alpha) significantly (P < 0.05) changed between 0, 10, and 20 U/kg heparin doses, but a difference between 20 and 30 U/kg could not be discerned secondary to loss of a detectable clot. The aPTT was significantly (P < 0.05) different between 0, 20, and 30 U/kg doses. ACT values were significantly different between the 0 U/kg heparin dose and all other doses; however, there were no significant differences between the 10, 20, and 30 U/kg heparin doses. Changes in anti-Xa activity were significantly linearly related to R (r = 0.81, P < 0.0001), alpha (r = -0.85, P < 0.0001), aPTT (r = 0.74, P < 0.0001), and ACT (r = 0.41, P = 0.005). In this model of small-dose heparin administration, TEG variables were more sensitive to changes in heparin activity than aPTT and ACT.ImplicationsChanges in thrombelastography (TEG) variables more sensitively reflect changes in circulating heparin activity than activated partial thromboplastin time (aPTT) and activated coagulation time (ACT) after small-dose heparin administration in rabbits. Thus, TEG may be more helpful than aPTT and ACT in the detection of heparin in both laboratory and clinical settings wherein heparin may play a role in coagulopathy.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…