Case Reports
Replacing the combitube by an endotracheal tube using a fibre-optic bronchoscope during spontaneous ventilation.
- L A Gaitini, S J Vaida, M Fradis, M Somri, B Yanovski, and N Kalderon.
- Department of Anaesthesia, Bnai Zion Medical Centre, Technion-Israel Institute of Technology, Haifa, Israel.
- J Laryngol Otol. 1998 Aug 1; 112 (8): 786-7.
AbstractWe present a case of microlaryngoscopy in a patient with an unexpectedly difficult airway. The airway was managed by using an oesophageal-tracheal Combitube (Kendall-Sheridan, Argyle, NY) (ETC) and a fibre-optic bronchoscope (Pentax-Japan-5 mm).