    [Reliability and survival of arterial catheters: optimal dynamic response].

    • M Riachy, E Riachy, G Sleilaty, G Dabar, A Yazigi, and G Khayat.
    • Service de pneumologie et de réanimation médicale, Hôtel-Dieu-de-France, rue Alfred-Naccache, Achrafieh, Beyrouth, Liban. riachy@dm.net.lb
    • Ann Fr Anesth Reanim. 2007 Feb 1; 26 (2): 119-24.

    ObjectivesBlood pressure is one of the most critical haemodynamic parameter in the intensive care unit (ICU). The measurement relies mainly on invasive methods (arterial lines) but also on noninvasive methods (Oscillometric and Manual). It is crucial to be instantaneous and accurate to adapt any decision making plan. The aim of this study is to evaluate the reliability of this measure given by an arterial catheter over time. This can determine the maintenance of catheter patency before clinical total occlusion.Study DesignObservational prospective study.Patients And MethodsDamping coefficient (xi) and natural frequency (Fn) of the arterial catheter system are studied in vivo each 12 hours by a fast flush test (FFT) in 61 patients. The measurements of the arterial blood pressure invasively (arterial catheter method) and non invasively (oscillometric method) are compared each 12 hours until the catheter is removed.ResultsAll over the study period for each catheter (till 240 hours), the mean arterial blood pressure measurements given by either the catheter method or the oscillometric method were very concordant (coefficient > 0.7). Only 3.39% of the catheters had their physical characteristics (xi and Fn) in the optimal zone at T0; reaching 66.67% at T19. The maximal inserted time was highly correlated with a good operating catheter (R = 0.739; P < 10(-4)).ConclusionThe measure of the arterial blood pressure invasively can still be reliable for a long period of time (10 days), as long as the catheter is inserted, especially when the mean arterial pressure is considered. Each time the distance of the catheter insertion site moves away 1 cm from the radiocarpal joint or the groin, the risk of troubleshooting is doubled; on each blood sample from the catheter, this risk is reduced by 20%.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…