• Rev Sci Instrum · Nov 2013

    Apparatus for simulating dynamic interactions between the spinal cord and soft-coupled intradural implants.

    • S Viljoen, H Oya, C G Reddy, B D Dalm, R Shurig, K Odden, G T Gillies, and M A Howard.
    • Department of Neurosurgery, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, Iowa 52242, USA.
    • Rev Sci Instrum. 2013 Nov 1; 84 (11): 114303.

    AbstractWe have designed, built, and tested an apparatus used for investigating the biomechanical response of a novel intradural spinal cord stimulator to the simulated physiological movement of the spinal cord within the thecal sac. In this apparatus, the rostral-caudal displacements of an anthropomorphic spinal cord surrogate can be controlled with a resolution of approximately 0.1% of a target value for up to 10(7) lateral movement cycles occurring at a repetition rate of 2 Hz. Using this system, we have been able to determine that the restoring force of the stimulator's suspension system works in concert with the frictional coupling between the electrode array and the surrogate to overcome the 0.42 μN inertial force associated with the lateral motion of the array. The result is a positional stability of the array on the surrogate (in air) of better than 0.2 mm over ~500,000 movement cycles. Design modifications that might lead to improved physiological performance are discussed.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.