• Pacing Clin Electrophysiol · Jan 1995

    Comparative Study

    Low incidence of lead related complications associated with nonthoracotomy implantable cardioverter defibrillator systems.

    • G J Fahy, J M Kleman, B L Wilkoff, V A Morant, and S L Pinski.
    • Department of Cardiology, Cleveland Clinic Foundation, Ohio 44195.
    • Pacing Clin Electrophysiol. 1995 Jan 1; 18 (1 Pt 2): 172-8.

    UnlabelledImplantable cardioverter defibrillators (ICDs) are increasingly being implanted without the need for thoracotomy. Long-term lead performance and stability were evaluated in 150 consecutive patients in whom 1 of 3 nonthoracotomy ICD lead systems was implanted over a 3-year period from September 1990.ResultsTwelve (8%) patients (7 males, 5 females) experienced 13 lead complications during a follow-up period of 12 +/- 10 months. Complications were related to intracardiac leads in 7 (4 dislodgments, 2 fractures, 1 right ventricular perforation) and patch leads in 6 (2 folding, 1 fracture, 1 erosion, and 2 hematomas) cases. Freedom from lead related complications at 1 year was 92% (95% confidence interval, 86%-95%). A significant difference in freedom from lead complications between the two most frequently implanted lead systems was observed (P = 0.02). Complication rates were similar in the initial 75 and the more recent 75 implants (P = 0.5). The median time between lead implant and detection of complications was 37 days (range 3-1,147). Complications were diagnosed before hospital discharge in only two cases. In five patients, complications were asymptomatic and in three of these, reoperation was required due to inadequate defibrillation thresholds. Reoperation was necessary in 9 of 12 patients.ConclusionsNonthoracotomy ICD lead systems are associated with a low complication rate. Complications may or may not cause symptoms, usually occur after hospital discharge, and require reoperation. Complications are not related to a "learning curve." There is a significant difference in performance between different lead systems.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…