    Ventricular fibrillation, automatic external defibrillators, and the United States Food and Drug Administration: confrontation without comprehension.

    • R O Cummins, R D White, and P E Pepe.
    • Department of Medicine, University of Washington, Seattle, USA.
    • Ann Emerg Med. 1995 Nov 1; 26 (5): 621-31; discussion 632-4.

    AbstractMore people die in the United States each day of potentially reversible VF than of any other cause of death, reversible or not. Early defibrillation is the definitive treatment. Automated external defibrillation is a proven technology now confirmed to have saved thousands of lives. As with all medical devices and technology, perfection is not possible. Some problems, such as those represented by the two cases discussed in this article, are inevitable and acceptable and give little cause for alarm. One would not stop penicillin from being manufactured and distributed because of a sudden, unexpected allergic reaction in one patient (error of commission) or an unexpected resistant organism in another (error of omission). The FDA must understand that AEDs, even if they are imperfect, are not anywhere near as dangerous as no defibrillator at all. AEDs have finally allowed many EMS systems to achieve early defibrillation. Discontinuing use of AEDs or closing AED manufacturers could mean a significant number of lives lost unnecessarily. Therefore EMS agencies planning to implement early-defibrillation programs should continue with such plans. Why the agents of an important federal regulatory agency have singled out this technology for an intense review puzzles many observers in the medical-device field. Two meetings have been hosted by officials of the FDA to discuss the continuing concern the FDA officials have expressed over automated defibrillation technology. These meetings included representatives from the AHA, the American College of Cardiology, ACEP, defibrillator manufacturers, and other interested organizations. The FDA leadership has repeatedly focused on data acquired through the FDA Medical Device Reporting systems. Congress requires the FDA to investigate reports of problems with "critical medical devices." Because the indication for the use of a defibrillator is cardiac arrest, there will inevitably be a high association between defibrillator use and patient deaths. FDA personnel may view such reports of device problems in association with patient deaths as evidence that an intrinsically flawed technology has reached the marketplace without rigorous testing and evaluation. From the clinician's perspective, however, these reports represent a small numerator over a huge denominator of daily, lifesaving clinical use. The non-FDA participants at the two meetings have stated that the FDA complaints appear to be random and reveal a lack of understanding of AED technology.(ABSTRACT TRUNCATED AT 400 WORDS)

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.